LP22AC01101 SFP 2x2 Cage Connector Press-Fit With Inner/Outer Light Pipe
P/N:
LP22AC01101
Manufacturer:
LINK-PP
Compatible Brand:
LINK-PP
Compatible P/N:
LP22AC01101
- Compatible Brands: LINK-PP
- Product Type: Cage
- Lightpipe Options: With Lightpipe
- PCB Termination: Through Hole - Press-Fit
- Operating Temperature (°C): -40-85
- Number of Ports: 2xN
- Connector Types: SFP
- P/N: LP22AC01101
- Manufacturer: LINK-PP
- Compatible Brand: LINK-PP
- Competitor P/N: LP22AC01101
Product Specifications
| LINK-PP Part Number | LP22AC01101 | Part Status | Active |
| Connector Style | Cage | Connector Type | SFP |
| Cage | COPPER ALLOY,Ni PL ATED | PACKAGING | TRAY PACKAGING |
| Port Matrix Configuration | 2x2 Port | Number of Ports | 4 |
| Operating Temperature Range | -40 – 85°C | Mounting Style | Through Hole, Right Angle |
| Included Lightpipe | Inner/Outer Light Pipe | Termination | Press-Fit |
| Height(Inches/mm) | 25.20/0.992 | Length (Inches/mm) | 63.25/2.490 |
| Width(Inches/mm) | 28.75/1.132 | EMI Containment Feature Type | EMI Springs |
LINK-PP LP22AC01101 2x2 Port SFP Stacked Cage with Inner/Outer Light Pipes
Engineered to maximize faceplate I/O density in demanding data center and telecommunications environments, the LINK-PP LP22AC01101 is a highly robust 2x2 (4-port) stacked SFP cage assembly. By organizing four Small Form-factor Pluggable (SFP) ports into a compact, ganged 2x2 matrix (28.75mm overall width), this right-angle cage empowers hardware architects to significantly increase port capacity on standard 1U or 2U networking chassis. Designed to envelop and shield PCB-mounted electrical receptacles, this cage provides essential mechanical alignment, structural protection, and thermal dissipation for high-speed pluggable transceivers.
Constructed from a premium Nickel-Plated Copper Alloy, this heavy-duty cage delivers superior structural rigidity and uncompromising resistance to corrosion. Featuring an extreme industrial operating temperature range of -40°C to +85°C, the LP22AC01101 guarantees mission-critical reliability for both climate-controlled enterprise data centers and unconditioned outdoor edge computing enclosures.
Integrated Inner & Outer Light Pipes for Visual Diagnostics
Providing clear, port-level diagnostic feedback in high-density 2x2 stacked configurations is a complex mechanical challenge. The LP22AC01101 definitively resolves this by incorporating precision-engineered Inner and Outer Light Pipes directly into the cage architecture.
- Comprehensive Port Visibility: These dedicated optical channels efficiently capture light from surface-mounted LEDs located on the PCB and route it directly to the front chassis bezel for both the upper and lower port rows simultaneously.
- Simplified Troubleshooting: Provides network administrators with immediate, unambiguous visual status indicators (such as Link Speed and Network Activity) for all four ports, without compromising the cage’s electromagnetic shielding or requiring complex external LED light-guides.
Advanced EMI Containment & Shielding
Managing Electromagnetic Interference (EMI) in high-density, multi-port chassis configurations is a critical design mandate. The LP22AC01101 achieves superior electromagnetic compatibility (EMC) through its advanced shielding construction.
- Nickel-Plated Copper Construction: The premium alloy acts as a continuous Faraday shield, aggressively containing internal high-frequency emissions generated by the PHY transceivers and ensuring strict compliance with FCC, CE, and CISPR regulatory standards.
- Active EMI Springs: Heavy-duty metallic EMI springs surround the perimeter of the port openings. These springs ensure continuous, low-impedance electrical contact with the metallic chassis bezel, aggressively sealing the enclosure against external Radio Frequency Interference (RFI).
- Port-to-Port Isolation: Internal metallic dividers between the upper and lower ports, as well as between adjacent columns, act as physical and electrical barriers. This dramatically reduces near-end crosstalk (NEXT) and electromagnetic coupling across the 4-port matrix.
Mechanical Design & Press-Fit PCB Integration
Hardware engineers prioritize long-term mechanical reliability alongside high-yield automated manufacturing. The LP22AC01101 leverages advanced solderless technology to optimize the PCB assembly workflow.
- Press-Fit (Compliant Pin) Technology: The cage utilizes a Through-Hole Press-Fit mounting style. The compliant pins are driven directly into plated through-holes (PTH) on the PCB, creating a cold-welded, gas-tight mechanical bond that heavily resists vibration, physical shock, and completely eliminates the thermal stress associated with secondary wave soldering.
- Tray Packaging for Automation: Supplied in standard tray packaging, ensuring component protection during transit and seamless integration into automated factory floor pick-and-place assembly lines.
Typical Applications
Combining massive stacked port density, targeted visual diagnostics, industrial-grade thermal resilience, and a robust press-fit design, the LP22AC01101 is the optimal interconnect housing for high-throughput network architectures:
- Data Center & Enterprise Switching: High-density Top-of-Rack (ToR) switches, core edge routers, and network aggregation devices demanding visually monitored, space-saving stacked port matrices.
- Telecommunications Infrastructure: Broadband access hubs, 5G baseband units (BBUs), and fiber-to-the-x (FTTX) optical line terminals (OLTs).
- Storage Area Networks (SAN): High-throughput Fibre Channel storage arrays and host bus adapters (HBAs) requiring dense physical layer protection.
- Industrial & Edge Computing: Ruggedized industrial Ethernet switches and micro-data center nodes deployed in extreme temperature environments (-40°C to +85°C).
Packaging, Shipping and Global Delivery for Networking Products
Anti-static packaging, shock-resistant protection, fast order dispatch, and reliable worldwide delivery for all LINK-PP networking products.
Anti-Static Protective Packaging
Protect networking products from electrostatic discharge and handling-related damage.
Shock-Resistant Transport Protection
Protect products against physical impacts during storage and international transportation.
Fast Order Processing and Dispatch
Accelerate order handling to ensure quick warehouse deployment.
Global Logistics and International Delivery
Ship products efficiently to customers across worldwide locations.
Technical Support and Deployment Assistance
LINK-PP provides expert technical support, from product selection and compatibility verification to deployment and long-term operation.
Pre-Sales Technical Consultation
Technical consultation to help you verify compatibility and select the appropriate product for your application.
Compatibility Verification Support
Verification support to help ensure compatibility with your equipment, applications, and deployment requirements.
Deployment & Installation Assistance
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Long-Term Technical Assurance
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
Industry Standards, Compliance and Quality Assurance
LINK-PP products are manufactured under recognized quality management systems and designed to support applicable industry standards, regulatory compliance, and long-term deployment requirements, including IEEE 802.3, RoHS, REACH, ISO 9001, and ISO 14001 where applicable. 「View Quality & Compliance Center」
ISO 9001 Quality Management
Manufactured under certified quality management processes to ensure consistent product quality and production control.
IEEE 802.3 Standards Compliance
Designed in accordance with applicable networking and Ethernet standards, including IEEE specifications where relevant.
RoHS Compliance
Manufactured using materials that support restrictions on hazardous substances for global market requirements.
REACH Compliance
Material declarations and supply chain processes support applicable REACH regulatory requirements.
Product Safety Assurance
Selected products support recognized safety and reliability requirements for networking applications.
Reliability Verification Testing
Products undergo verification and quality testing to support stable operation in enterprise, telecom, and industrial environments.
Warranty and After-Sales Service
LINK-PP provides warranty coverage and after-sales support to help ensure stable operation and long-term product performance.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
Keyword:
Download
Product Drawing
FAQ
Recommend
-
Nav Menu
-
About LINK-PP
-
All Products
-
Applications







































