Data Center Interconnect Solutions for 100G, 400G & 800G Networks
LINK-PP supports high-capacity optical connectivity between distributed data centers with direct Ethernet optics, coherent ZR/ZR+ pluggables, DWDM-ready interfaces and high-speed 100G, 400G and 800G transceiver families for campus, metro and regional DCI.
Quick answer: Data Center Interconnect (DCI) connects geographically separated data centers so applications, storage, compute clusters and network services can exchange traffic over high-capacity links. Depending on distance, available fiber and operational ownership, the physical layer may use direct Ethernet optics, coherent ZR/ZR+ pluggables, DWDM transport or a carrier-provided wavelength service.
Where Data Center Interconnect Is Used
DCI requirements change with geography, fiber ownership, traffic profile and the amount of capacity that must move between sites.
Adjacent Facilities and Dedicated Fiber
Shorter inter-building links may use direct Ethernet optics when the host ports, fiber path and optical budget support the target reach.
High-Capacity Links Across a Metropolitan Area
Metro links increasingly use coherent pluggables over dark fiber or DWDM where spectral efficiency and fiber utilization matter.
Extended Optical Transport Between Sites
Regional interconnects require closer attention to OSNR, dispersion, amplification, line-system compatibility and coherent operating mode.
Interconnecting Distributed Compute Facilities
Distributed AI and high-performance workloads can drive sustained inter-site traffic, making 400G/800G capacity, latency and redundant optical paths important design factors.
How Data Center Interconnect Networks Are Structured
The optical architecture changes depending on whether the sites are connected by a dedicated fiber pair, coherent wavelengths, a DWDM line system or a carrier-managed transport service.
Direct Ethernet DCI
-
TOPOLOGYPoint-to-Point FiberA direct optical path can be appropriate when the required reach fits the Ethernet PMD and the fiber route is simple.
-
OPTICSDirect-Detect TransceiversThe module remains an Ethernet optical interface rather than a coherent wavelength endpoint.
-
VERIFYOptical BudgetConfirm fiber attenuation, connectors, splices and module limits before assuming a short DCI link is viable.
Direct-Detect vs Coherent Optics for DCI
DCI does not automatically mean coherent optics. The optical method should follow the link reach, fiber resources, host capabilities and capacity plan.
How to Choose a DCI Architecture
Start with the physical route and fiber ownership before selecting a coherent module. The optic is one component inside the transport design, not the design itself.
Coherent Optics for DCI: 400ZR, ZR+ and 800G
Coherent pluggables move more transport intelligence into the router or switch port. The appropriate family depends on standards support, optical reach, line-system design, power and cooling.
Standardized Metro DCI
Designed around interoperable coherent operation for data center interconnect and metro applications where predictable host and line-system behavior is important.
Extended Coherent Modes
Used where additional optical margin, rate flexibility or amplified transport is required beyond a basic ZR deployment.
Higher Capacity per Wavelength
Moves DCI toward 800G-class coherent transport, increasing the importance of host power, thermal design and line-system compatibility.
CMIS & Telemetry
Coherent pluggables depend on detailed module management, power-state behavior and performance telemetry for production troubleshooting.
Dark Fiber vs Managed Wavelength Services
The choice changes who owns the optical layer, how much control the network team has and where engineering responsibility sits.
Control the Optical Layer
Dedicated fiber lets the operator choose endpoint optics, coherent modes, wavelength plan and DWDM architecture. It offers more control but also requires optical engineering, monitoring and operational ownership.
Consume Capacity as a Service
A carrier or service provider operates the underlying optical transport. The data center team focuses on the service handoff and capacity requirement rather than managing amplifiers, ROADMs or wavelength engineering.
When Does IP-over-DWDM Simplify DCI?
Coherent pluggables can collapse a traditional transponder layer by placing the coherent wavelength directly in a router or switch, but only when the host and optical line system support the required mode.
Router → Client Optic → Transponder → DWDM
The packet and optical transport layers use separate endpoint hardware. This can offer clear operational separation but adds equipment, power and management layers.
Router / Switch → Coherent Pluggable → DWDM
400ZR, ZR+ and later coherent pluggables can map packet traffic directly onto a wavelength, reducing the number of intermediate optical devices where the architecture permits.
Read the IP-over-DWDM Guide →Scaling DCI Capacity with DWDM
DWDM increases the usable capacity of a fiber pair by carrying multiple optical wavelengths. The usable wavelength count and line rate depend on the channel plan and optical line system.
Engineering Constraints That Determine DCI Reach
Coherent reach is a system result. A transceiver data sheet alone cannot establish whether a production path will close with adequate margin.
Fiber Attenuation
Account for span loss, connectors, splices, patching and passive optical components across the end-to-end path.
OSNR
Coherent receivers require sufficient optical signal-to-noise ratio after amplification, filtering and multi-span transport.
Chromatic Dispersion
Modern coherent DSP compensates significant dispersion, but the supported operating window still depends on mode and implementation.
Amplification & Filtering
EDFAs, ROADMs, mux/demux filters and open line systems add gain, loss and noise that must be modeled together.
FEC & Coherent Profile
Modulation, symbol rate and FEC determine the trade-off between line rate, optical tolerance, latency and reach.
DCI for AI Scale-Across Networks
When compute capacity spans multiple facilities, the inter-site optical network becomes part of the application performance envelope rather than a background transport service.
Sustained Inter-Site Traffic
Distributed training, checkpoint movement and dataset replication can create sustained east-west traffic between facilities.
Predictable Optical Paths
Path length, coherent processing and intermediate transport elements affect end-to-end latency and jitter.
400G / 800G Scaling
Higher per-port and per-wavelength rates reduce the number of physical interfaces required for very large inter-site bandwidth targets.
Redundant Fiber Paths
Production scale-across designs should evaluate route diversity, protection strategy and failure domains, not only raw bandwidth.
Coherent Optics Must Match the Host and the Optical Line
A QSFP-DD or OSFP module can physically fit a host and still fail because of unsupported power class, coherent mode, management interface, firmware behavior or line-system assumptions.
Form Factor, Power & Cooling
Verify the router or switch receptacle, supported module power envelope, airflow and high-power operating state before deployment.
CMIS & Firmware
Coherent modules rely on detailed management, power-state transitions and telemetry that must be supported by the host software.
Mode & Line-System Support
Confirm coherent profile, wavelength plan, launch power, FEC and compatibility with passive or amplified DWDM components.
Cisco
Validate coherent pluggable support, port power, CMIS behavior and line-system mode on the exact routing or switching platform.
Arista
Confirm EOS support, host interface behavior, module management and supported coherent or DWDM operating modes.
Juniper
Check platform-specific coherent optic support, firmware requirements, port configuration and optical management capability.
NVIDIA
For data center switching environments, verify protocol role, port form factor, thermal budget and whether the application is Ethernet, InfiniBand or transport-facing.
Typical Data Center Interconnect Optical BOM
The exact bill of materials depends on whether the design is direct fiber, passive DWDM, amplified DWDM or a carrier service handoff.
Optical Product Families for DCI Planning
These are existing LINK-PP product families relevant to DCI projects. Confirm the exact coherent mode, protocol and host compatibility at the individual model level before deployment.
100G QSFP28 / SFP-DD
100G optical transceivers for installed-base, aggregation and transport-adjacent DCI requirements.
View 100G Products →400G QSFP-DD / OSFP / QSFP112
400G high-speed optical modules including form factors used in modern DCI and coherent-pluggable ecosystems.
View 400G Products →800G QSFP-DD / OSFP
800G optical module families for next-generation data center and high-capacity interconnect applications.
View 800G Products →200G / 400G / 800G Transceivers
Browse the broader high-speed transceiver portfolio when planning mixed-generation optical upgrades.
View High-Speed Portfolio →Data Center Interconnect Engineering Resources
Use these existing LINK-PP guides for the deeper coherent, DWDM and optical-transport details that should not be duplicated inside the solution page.
DCI & Coherent
Economics & AI
Engineering Support
Data Center Interconnect FAQ
Common architecture and optics questions for campus, metro and regional DCI projects.
What is Data Center Interconnect (DCI)?
Data Center Interconnect connects geographically separated data centers so applications, storage, compute and network services can exchange traffic over high-capacity links. Depending on distance and fiber availability, DCI may use direct Ethernet optics, coherent pluggables, DWDM or carrier-provided wavelength services.
What is the difference between direct-detect and coherent optics for DCI?
Direct-detect Ethernet optics are generally considered for shorter point-to-point links, while coherent optics add DSP-based coherent transmission for higher spectral efficiency, DWDM integration and longer metro or regional paths. The correct choice depends on reach, fiber loss, host support and optical design.
What is the difference between 400ZR and ZR+?
400ZR targets standardized coherent interoperability for DCI and metro applications, while ZR+ families extend operating modes and optical reach for more demanding amplified or regional transport. Actual reach depends on coherent mode, fiber loss, OSNR, dispersion and line-system design.
When does DCI require DWDM?
DWDM becomes useful when multiple high-capacity wavelengths must share the same fiber pair, when fiber resources are limited, or when coherent pluggables need to integrate with an optical line system. Channel plan, insertion loss, amplification and OSNR must be validated.
Can 800G coherent optics be used for data center interconnect?
800G coherent optics are designed for high-capacity DCI and transport use cases, but deployment requires compatible host ports, coherent operating modes, sufficient module power and cooling, and an optical path that meets the required OSNR and link budget.
What determines the maximum reach of a coherent DCI link?
Reach is determined by the coherent mode, launch power, receiver sensitivity, fiber attenuation, chromatic dispersion, OSNR, amplifier plan, ROADM or filter losses, FEC and the optical line system. A nominal ZR or ZR+ label alone does not establish the supported distance.
Plan the Optical Layer Before Ordering DCI Optics
Send the host platform, site-to-site distance, fiber ownership, target capacity and existing optical line-system information. LINK-PP can map the requirement to relevant transceiver families and compatibility checks.
Review the DCI Architecture
Share topology, fiber route, line rate and optical transport model for an architecture-level review.
Contact Engineering →Verify Coherent Optics Compatibility
Provide host model, firmware, coherent mode and DWDM path information for compatibility review.
Request Compatibility Review →Request DCI Optics Pricing
Provide part numbers, quantities and deployment schedule for pricing, lead-time and sample planning.
Request a Quote →-
Nav Menu
-
About LINK-PP
-
All Products
-
Applications