LP0806PANL Hipot 3000 Vrms THT 4 Pin Converter Isolation Modules
P/N:
LP0806PANL
Manufacturer:
LINK-PP
Compatible Brand:
LINK-PP
Compatible P/N:
LP0806PANL
- Compatible Brands: LINK-PP
- Mounting Type: THT
- Turns Ratio TX: 1CT:1CT
- Temperature: -40℃ TO +85°C
- P/N: LP0806PANL
- Manufacture: LINK-PP
- Compatible Brand: LINK-PP
- Compatible P/N: LP0806PANL
Packaging Details:
N.W/pCS:
0.001kg
Package:
Tube
SPQ:
58pcs
Qty/carton:
6380pcs
Carton size:
54*17*17cm
G.W/carton:
9.1kg
Product Specifications
| LINK-PP Part Number | LP0806PANL | Transformer Type | Lan Transformer |
| Part Status | Active | Turns Ratio - Primary: Secondary | 1:1 Transmitter, 1:1 Receiver |
| Construction | OPEN FRAME | Application-Lan | - |
| Number of Ports | SINGLE | Speed | - |
| Package | Tape & Reel | Cores per Port | 1 |
| AutomDX | Yes | Isolation Voltage | 3000Vrms |
| PIN Number | 4 | Mounting Type | THT |
| Package Height (Inches/mm) | 0.25/6.35 | Package Length (Inches/mm) | 0.50/12.70 |
| Package Width (Inches/mm) | 0.35/8.89 | Temperature | -40℃ TO +105℃ |
| Turns Ratio RX/TX | 1CT:1CT | Configuration RX/TX | T,C,S |
Single-Port 3000Vrms High-Isolation THT LAN Transformer
The LINK-PP LP0806PANL is a high-isolation single-port discrete LAN magnetic transformer module in a 4-pin through-hole (THT) open-frame configuration. Engineered with a single-core magnetic architecture, 1:1 turns ratio (1CT:1CT), integrated T, C, S configuration, and AutoMDX support, the module provides 3000Vrms dielectric isolation and common-mode signal coupling across an extended operating temperature range of -40℃ TO +105℃.
The mechanical package features an open-frame body measuring 6.35 mm (0.25 inches) in height, 12.70 mm (0.50 inches) in length, and 8.89 mm (0.35 inches) in width, supplied in Tape & Reel packaging. Delivering high dielectric breakdown protection within a compact footprint, the LP0806PANL provides specialized board-level magnetics suited for battery management systems (BMS), solar inverters, smart utility meters, motor drive controllers, and industrial power distribution equipment.
Design Positioning and Qualification
The LINK-PP LP0806PANL is designed as a high-isolation discrete LAN transformer module for hardware architectures requiring reinforced galvanic protection and extended thermal durability. It can be evaluated for new hardware designs, BOM consolidation, or as an alternative sourcing option for standard 4-pin through-hole 3000Vrms isolation transformer footprints operating across -40℃ TO +105℃. Engineering teams should verify pinout mapping, PCB through-hole drill dimensions, creepage distances, and circuit schematics against the official LINK-PP technical drawing before approving production release.
Procurement and OEM Qualification
For sourcing teams and OEM engineering programs evaluating the LP0806PANL as a second-source or BOM alternative, key qualification parameters include PCB mechanical footprint, pinout alignment, lead solderability, electrical isolation parameters, operating temperature rating, and expected volume demand. LINK-PP can support sample evaluation, mechanical drawing review, and documentation requirements for prototype validation, AVL qualification, and volume production planning.
Reinforced 3000Vrms Isolation and High-Temperature Design
Implementing 3000Vrms isolation in a 4-pin through-hole transformer module provides specific safety and thermal advantages for power-sensitive electronic designs:
- 3000Vrms Dielectric Isolation: The 3000Vrms specification defines the high-voltage dielectric withstand rating, providing reinforced safety barriers between high-voltage power domains and low-voltage digital control circuits.
- -40℃ TO +105℃ Extended Operating Range: The -40℃ TO +105℃ specification defines the stated operating temperature range of the transformer assembly, supporting equipment deployed in unventilated power conversion enclosures and high-temperature industrial environments.
- Compact 4-Pin Through-Hole Profile: The 4-pin THT package (12.70 mm length × 8.89 mm width × 6.35 mm height) enables layout designers to establish wide isolation creepage distances across board layers while minimizing PCB real estate.
- Open-Frame Construction: Reduces total component mass and allows natural convective heat transfer around the magnetic core in dense industrial sub-assemblies.
- Through-Hole Mechanical Stability: Through-hole pin mounting provides mechanical anchoring into the FR4 PCB, ensuring physical joint integrity under continuous high-vibration operating conditions.
Internal Magnetics Architecture, 1:1 Turns Ratio, and AutoMDX
The LP0806PANL incorporates an internal single-core magnetic architecture utilizing specialized high-dielectric insulation to support the 3000Vrms isolation barrier. A symmetrical 1:1 turns ratio (1CT:1CT) across primary and secondary stages in a T, C, S configuration enables broad interface compatibility with standard transceiver and line-driver architectures.
The module is designed for interfaces supporting AutoMDX operation, allowing automatic line crossover detection when coupled with compatible PHY transceivers. Electrical isolation is specified according to the applicable product documentation, separating sensitive controller electronics from high-voltage transient surges, common-mode noise, and line-side faults.
Mechanical Envelope and PCB Layout Considerations
When integrating the LP0806PANL into host hardware layouts, engineering teams should observe the following structural and layout guidelines:
1. Package Dimensions and Vertical Clearance
The module body measures 12.70 mm (0.50 inches) in length, 8.89 mm (0.35 inches) in width, and 6.35 mm (0.25 inches) in height. Designers should verify that component spacing accommodates the 4-pin footprint and allows adequate clearance for adjacent high-voltage safety barriers.
2. High-Voltage Creepage and PCB Clearance Barrier
To preserve the 3000Vrms dielectric isolation rating, host PCB designers must maintain an unbroken creepage and clearance barrier directly beneath the component between the primary-side and secondary-side pins. High-voltage isolation slots (milled PCB cutouts) can be placed between pin rows where necessary to meet system-level safety standards.
3. 4-Pin Through-Hole Layout and Drill Tolerances
The component features 4 through-hole leads. Verification of plated-through-hole drill diameters, pad sizes, and annular rings against the official footprint drawing is essential to ensure proper solder fill and mechanical stability during wave or selective soldering.
4. Thermal Design up to +105℃
Because the module is rated for operation up to +105℃, system designers should confirm that localized ambient air temperatures inside enclosed power cabinets remain within this thermal window under full electrical load conditions.
Design Consideration Comparison: High-Isolation THT Transformer vs. Alternative Implementations
| Design Consideration | LP0806PANL 3000Vrms THT Transformer |
Standard Discrete 1500Vrms LAN Transformer |
Integrated RJ45 MagJack |
|---|---|---|---|
| Dielectric Isolation Rating | 3000Vrms (High Hipot) | 1500Vrms (Standard Functional) | 1500Vrms (Standard Functional) |
| Operating Temperature Range | -40℃ TO +105℃ (Extended Industrial) | 0°C to +70°C or -40°C to +85°C | 0°C to +70°C or -40°C to +85°C |
| Mounting Architecture | 4-Pin Through Hole (THT) | Multi-Pin Surface Mount (SMD) | Through-Hole / Hybrid at Board Edge |
| Physical Connector Flexibility | Complete flexibility (RJ45, terminals, M12) | Complete flexibility (RJ45, terminals, M12) | Fixed RJ45 port geometry |
| Primary-to-Secondary Creepage | High physical spacing across 4-pin barrier | Constrained by fine-pitch SMD lead spacing | Constrained within RJ45 connector housing |
| Primary Engineering Focus | High-voltage safety barrier & high heat | Standard data coupling & SMT assembly | Board-edge connector consolidation |
Application Considerations for LP0806PANL
| Target Application Profile | Primary Engineering Consideration |
|---|---|
| Battery Management Systems (BMS) | 3000Vrms isolation protects low-voltage monitoring processors from high-voltage DC battery string potentials. |
| Solar Inverters & Power Conversion | -40℃ TO +105℃ rating maintains magnetic coupling stability in unventilated outdoor power conversion cabinets. |
| Smart Utility Meters & Grid Telemetry | Provides high dielectric barrier protection against power-line transient surges in utility metering hardware. |
| Industrial Motor Drives & Actuators | Isolates control logic from severe common-mode voltage spikes generated by high-power switching stages. |
Engineering Verification Checklist
Before releasing a PCB layout or finalizing a bill of materials using the LP0806PANL, hardware engineers should confirm the following design parameters against official documentation:
- Creepage and Clearance Verification: Verify that board-level creepage distances between primary and secondary pins satisfy system safety standards for 3000Vrms isolation.
- Through-Hole Drill Geometry: Confirm 4-pin drill diameters, hole spacing, and pad sizes against the official LINK-PP LP0806PANL drawing.
- Turns Ratio and Circuit Matching: Confirm that the 1:1 turns ratio (1CT:1CT) and T, C, S configuration match the transceiver or controller reference schematic.
- High-Voltage Dielectric Testing: Verify that production hipot test parameters comply with the 3000Vrms rating and isolation test limits.
- Soldering Process Compatibility: Confirm that wave, selective, or manual soldering profiles adhere to recommended thermal limits for open-frame THT components.
- Thermal Operating Environment: Ensure that the operating environment inside the equipment chassis remains within the specified -40℃ TO +105℃ extended temperature range.
Frequently Asked Questions
What are the primary specifications of the LINK-PP LP0806PANL?
The LP0806PANL is a single-port 3000Vrms high-isolation discrete LAN magnetic transformer module. It features a 4-pin through-hole (THT) open-frame construction, a 1-core magnetic architecture, 1:1 turns ratio (1CT:1CT), AutoMDX support, Tape & Reel packaging, and an extended operating temperature range of -40℃ TO +105℃.
Why is a 3000Vrms isolation voltage required instead of standard 1500Vrms?
While standard commercial networking equipment typically requires 1500Vrms functional isolation, safety-critical systems—such as high-voltage battery management systems (BMS), solar inverters, and power grid automation—require reinforced isolation barriers up to 3000Vrms to protect operators and control circuitry from severe electrical faults and common-mode surges.
What are the design implications of the -40℃ TO +105℃ operating temperature range?
The -40℃ TO +105℃ specification defines the stated operating temperature range of the transformer assembly. This extended temperature rating allows the component to be specified in power conversion electronics, automotive environments, and unconditioned industrial cabinets where localized internal temperatures exceed the standard 85°C industrial limit.
What PCB layout rules are necessary to maintain 3000Vrms isolation?
To preserve the 3000Vrms isolation barrier, a continuous copper keep-out zone must be maintained across all PCB layers directly beneath the transformer between primary and secondary pins. No traces, planes, or vias should cross this barrier, and milled PCB isolation slots may be implemented to increase surface creepage distance.
Why choose a 4-pin through-hole discrete transformer module?
A 4-pin discrete module provides layout designers with the flexibility to place the isolation stage exactly where safety boundaries require it on the board, while allowing custom connector selection (such as high-voltage terminal blocks, M12 connectors, or custom headers). The through-hole mounting also provides robust mechanical anchoring against physical vibration.
Can the LP0806PANL be evaluated as an alternative sourcing option in existing designs?
Yes. The LP0806PANL can be evaluated as an alternative sourcing option for standard 4-pin THT high-isolation transformer footprints. Engineering teams should cross-reference pinout mapping, package dimensions (12.70 mm length, 8.89 mm width, 6.35 mm height), and 3000Vrms isolation specifications against official manufacturer drawings before approving component substitution.
Packaging, Shipping and Global Delivery for Networking Products
Anti-static packaging, shock-resistant protection, fast order dispatch, and reliable worldwide delivery for all LINK-PP networking products.
Anti-Static Protective Packaging
Protect networking products from electrostatic discharge and handling-related damage.
Shock-Resistant Transport Protection
Protect products against physical impacts during storage and international transportation.
Fast Order Processing and Dispatch
Accelerate order handling to ensure quick warehouse deployment.
Global Logistics and International Delivery
Ship products efficiently to customers across worldwide locations.
Technical Support and Deployment Assistance
LINK-PP provides expert technical support, from product selection and compatibility verification to deployment and long-term operation.
Pre-Sales Technical Consultation
Technical consultation to help you verify compatibility and select the appropriate product for your application.
Compatibility Verification Support
Verification support to help ensure compatibility with your equipment, applications, and deployment requirements.
Deployment & Installation Assistance
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Long-Term Technical Assurance
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
Industry Standards, Compliance and Quality Assurance
LINK-PP products are manufactured under recognized quality management systems and designed to support applicable industry standards, regulatory compliance, and long-term deployment requirements, including IEEE 802.3, RoHS, REACH, ISO 9001, and ISO 14001 where applicable. 「View Quality & Compliance Center」
ISO 9001 Quality Management
Manufactured under certified quality management processes to ensure consistent product quality and production control.
IEEE 802.3 Standards Compliance
Designed in accordance with applicable networking and Ethernet standards, including IEEE specifications where relevant.
RoHS Compliance
Manufactured using materials that support restrictions on hazardous substances for global market requirements.
REACH Compliance
Material declarations and supply chain processes support applicable REACH regulatory requirements.
Product Safety Assurance
Selected products support recognized safety and reliability requirements for networking applications.
Reliability Verification Testing
Products undergo verification and quality testing to support stable operation in enterprise, telecom, and industrial environments.
Warranty and After-Sales Service
LINK-PP provides warranty coverage and after-sales support to help ensure stable operation and long-term product performance.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply