Brocade QSFP28-100G-AOC-3M Compatible LINK-PP LQ-AOC11100-3M 100G QSFP28 Active Optical Cable 3m (10ft)
P/N:
LQ-AOC11100-3M
Manufacturer:
LINK-PP
Compatible Brand:
Brocade
Compatible P/N:
QSFP28-100G-AOC-3M
- Compatible Brands: Brocade
- Form Factor: QSFP28
- Data Rate: 100G
- Wavelength: 850nm
- Cable Length: 3m
- P/N: LQ-AOC11100-3M
- Manufacture: LINK-PP
- Compatible Brand: Brocade
- Compatible P/N: QSFP28-100G-AOC-3M
Product Specifications
| LINK-PP Part Number | LQ-AOC11100-3M | Brocade Part Number | QSFP28-100G-AOC-3M |
| Form Factor | QSFP28 to QSFP28 | Max Data Rate | 100Gbps |
| Cable Length | 3m (10ft) | Cable Type | Optical Cable |
| Wavelength | 850nm | Minimum Bend Radius | 7.5mm |
| Transmitter Type | VCSEL | Receiver Type | PIN |
| Power supply | 3.3V | CDR | Support |
| Case Temperature | 0 to 70°C | Protocols | 100G Ethernet |
Brocade QSFP28-100G-AOC-3M Compatible LINK-PP LQ-AOC11100-3M 100G QSFP28 Active Optical Cable (3-Meter, QSFP28 to QSFP28) for Brocade Switching Fabrics
The LINK-PP LQ-AOC11100-3M is a high-performance, Brocade QSFP28-100G-AOC-3M compatible 4-channel, pluggable, parallel 100G QSFP28 Active Optical Cable (AOC) engineered for short-range 100 Gigabit Ethernet and InfiniBand EDR (Enhanced Data Rate) applications. Factory-terminated and pre-sealed with 3 meters (10 feet) of lightweight multimode fiber, this active optical assembly provides a seamless, plug-and-play interconnect solution for high-density Brocade routing and switching environments.
Integrating four independent transmitter and receiver channels operating at data rates up to 25.78Gbps per lane, the cable achieves an aggregate bandwidth of 100Gbps. Built with an 850nm VCSEL laser array, high-sensitivity PIN photodiode receivers, and integrated Clock and Data Recovery (CDR) circuits on both transmit and receive channels, it guarantees clean eye diagrams and low jitter over short distances. Fully compliant with SFF-8665, SFF-8636, and IEEE 802.3bm 100GBASE-SR4 standards, the LQ-AOC11100-3M offers network architects a reliable, zero-EMI alternative to bulky copper DAC cables and separate optical transceivers across Brocade ICX, VDX, and SLX platforms.
Application Topologies and Deployment Scenarios
Active Optical Cables bridge the gap between heavy, reach-limited direct attach copper (DAC) cables and expensive optical transceivers paired with patch cords. The 3-meter length is specifically optimized for high-density intra-rack and adjacent-rack routing in Brocade environments.
In-Rack and Adjacent-Rack Brocade Switch-to-Server Interconnects
In modern enterprise data centers and campus cores, 100G Top-of-Rack (ToR) switches (such as the Brocade ICX 7850, ICX 7650, or VDX Series) aggregate traffic from high-performance servers equipped with 100G SmartNICs. At 3 meters, this AOC provides the ideal span to route from ToR switches down to compute nodes located in the middle or bottom of the same cabinet, or across to adjacent server racks, without cable slack cluttering cable management trays.
High-Density InfiniBand EDR & HPC Compute Clusters
For supercomputing and High-Performance Computing (HPC) clusters utilizing InfiniBand EDR protocol (100Gbps aggregate), low latency and zero packet loss are mandatory. This AOC provides the ultra-wide pipeline and low-jitter signal path required for inter-node communication, storage array uplinks, and clustering compute chassis connected via Brocade fabric switches.
Replacing Bulky Copper DAC Cables in Airflow-Constrained Racks
Passive copper DAC cables at 3 meters become thick (typically 26AWG or 30AWG), heavy, and difficult to bend, severely restricting hot-aisle exhaust airflow. The LQ-AOC11100-3M uses thin optical fiber, reducing cable bundle volume by over 70% and significantly improving chassis airflow efficiency in high-density Brocade switch racks.
Physical Layer Design and Optoelectronic Architecture
Engineered for continuous commercial operation (0°C to 70°C), this AOC combines advanced micro-optics with highly flexible cable construction.
4-Channel 850nm VCSEL & Integrated CDR Architecture
Each QSFP28 connector head houses an electro-optical engine containing a 4-channel 850nm VCSEL (Vertical-Cavity Surface-Emitting Laser) array and a matched PIN photodiode array. To combat signal degradation over high-speed 25G NRZ electrical host interfaces, both ends of the cable feature integrated TX & RX Clock and Data Recovery (CDR) circuits. The CDR re-times the electrical signals, suppressing jitter and ensuring strict compliance with switch port receiver sensitivity limits.
Ultra-Flexible 7.5mm Bend Radius and Zero EMI Performance
Unlike copper cabling which suffers from signal degradation when bent, the multimode optical fiber core inside this AOC supports a tight minimum bend radius of 7.5mm. This extreme flexibility allows technicians to route cables through tight chassis corners and dense cable organizers without risking micro-bends or link degradation. Furthermore, because data travels as light through dielectric optical fiber, the cable is 100% immune to Electromagnetic Interference (EMI) and radio frequency crosstalk.
Low Power Consumption and Thermal Efficiency
Power efficiency is critical in high-density switch faceplates populated with dozens of 100G ports. Operating from a single +3.3V power supply, this active optical cable consumes significantly less power than driving traditional long-reach optical transceivers, helping to keep Brocade switch chassis line card temperatures low.
Multi-Vendor Compatibility and Digital Diagnostics
The LQ-AOC11100-3M undergoes rigorous hardware validation to ensure flawless operation across Brocade hardware ecosystems.
Brocade Hardware and OS Compatibility Validation
Undergoing stringent EEPROM coding, the LQ-AOC11100-3M is natively recognized by Brocade operating systems (FastIron OS, Network OS, and SLX-OS) as a QSFP28-100G-AOC-3M active optical cable. It ensures immediate plug-and-play deployment in Brocade ICX, VDX, and SLX Series switches and routers without triggering "unsupported optic" warnings, interface alarms, or port lock-outs.
Real-Time DOM/DDM Monitoring via Brocade CLI
Integrated Digital Diagnostic Monitoring (DDM) accessible via Brocade CLI (e.g., show optic or show media) or SNMP polling allows network administrators to monitor real-time operating parameters of both connector heads. Telemetry data includes Transceiver Temperature, Vcc Supply Voltage, and individual TX Bias Current, enabling NOC personnel to track cable health proactively.
Selection Guide and Deployment Considerations
Choosing between DAC, AOC, and optical modules depends on distance, bend radius requirements, and maintenance preferences.
AOC vs. DAC vs. Transceiver + Fiber Patch Cord
- Active Optical Cable (This Product): Pre-terminated, factory-sealed optical assembly. Zero risk of optical end-face contamination (no cleaning required). Lighter and thinner than DAC. Ideal for 3m to 30m in-rack and rack-to-rack interconnects.
- Direct Attach Copper (DAC): Lower cost for very short distances (1m to 2m), but heavy, stiff, and limited in reach due to copper attenuation at 25G per lane.
- Transceivers + Optical Cable: Requires buying two separate 100GBASE-SR4 transceivers and an MPO patch cord. Higher cost and requires strict optical end-face cleaning before insertion.
Cable Routing and Fiber Handling Guidelines in Brocade Chassis
- Bend Radius: Respect the 7.5mm minimum bend radius during installation. Do not tie cable zip-ties too tightly around the optical jacket to avoid crushing internal fiber strands.
- Dust Caps: Leave the protective vinyl dust caps on the QSFP28 connector heads until the exact moment of insertion into the Brocade switch port.
- Hot-Pluggable: The cable supports hot-swapping; it can be plugged or unplugged from active Brocade ports without cycling host system power.
Packaging, Shipping and Global Delivery for Networking Products
Anti-static packaging, shock-resistant protection, fast order dispatch, and reliable worldwide delivery for all LINK-PP networking products.
Anti-Static Protective Packaging
Protect networking products from electrostatic discharge and handling-related damage.
Shock-Resistant Transport Protection
Protect products against physical impacts during storage and international transportation.
Fast Order Processing and Dispatch
Accelerate order handling to ensure quick warehouse deployment.
Global Logistics and International Delivery
Ship products efficiently to customers across worldwide locations.
100G QSFP28 Technical Support and Deployment Assistance
LINK-PP provides expert technical support, from product selection and compatibility verification to deployment and long-term operation.
Pre-Sales Technical Consultation
Technical consultation to help you verify QSFP28-100G-AOC-3M compatibility and select the appropriate product for your application.
Compatibility Verification Support
Verification support to help ensure compatibility with your equipment, applications, and deployment requirements.
Deployment & Installation Assistance
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Long-Term Technical Assurance
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
Industry Standards, Compliance and Quality Assurance
LINK-PP products are manufactured under recognized quality management systems and designed to support applicable industry standards, regulatory compliance, and long-term deployment requirements, including IEEE 802.3, RoHS, REACH, ISO 9001, and ISO 14001 where applicable. 「View Quality & Compliance Center」
ISO 9001 Quality Management
Manufactured under certified quality management processes to ensure consistent product quality and production control.
IEEE 802.3 Standards Compliance
Designed in accordance with applicable networking and Ethernet standards, including IEEE specifications where relevant.
RoHS Compliance
Manufactured using materials that support restrictions on hazardous substances for global market requirements.
REACH Compliance
Material declarations and supply chain processes support applicable REACH regulatory requirements.
Product Safety Assurance
Selected products support recognized safety and reliability requirements for networking applications.
Reliability Verification Testing
Products undergo verification and quality testing to support stable operation in enterprise, telecom, and industrial environments.
100G QSFP28 Warranty and After-Sales Service
LINK-PP provides warranty coverage and after-sales support to help ensure stable operation and long-term product performance.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply