FS QSFP28-SR4-100G 100m 850nm 100GBASE QSFP28 SR4 OM4 DOM MPO-12 MMF Optical Transceiver Module,4x 25G-SR
P/N:
LQ-M85100-SR4C
Manufacturer:
LINK-PP
Compatible Brand:
FS
Compatible P/N:
QSFP28-SR4-100G
- Compatible Brands: FS
- Form Factor: QSFP28
- Data Rate: 100G
- Distance: ≤100m
- Type: Multimode
- Connector: MTP/MPO-12
- Model: SR4
- Wavelength: 850nm
- P/N: LQ-M85100-SR4C
- Manufacture: LINK-PP
- Compatible Brand: FS
- Compatible P/N: QSFP28-SR4-100G
Product Specifications
| LINK-PP Part Number | LQ-M85100-SR4C | FS Part Number | QSFP28-SR4-100G |
| Form Factor | QSFP28 | Max Data Rate | 100Gbps |
| Wavelength | 850nm | Max Cable Distance | 70m@OM3/100m@OM4 |
| Connector | MTP/MPO-12 | Media | MMF |
| Transmitter Type | VCSEL 850nm | Receiver Type | PIN |
| Power Consumption | ≤3.3W | Extinction Ratio | >3dB |
| DDM/DOM | Supported | Case Temperature range | 0°C to +70°C |
| TX Power | -8.4~2.4dBm | Minimum Receiver Power | -10.3dBm |
| Powerbudget | 1.9dB | Receiver Overload | 2.4dBm |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR | Inbuilt FEC | No |
| Protocols | IEEE 802.3bm, QSFP28 MSA, SFF-8665, SFF-8636, RoHS, CPRI, eCPRI | Warranty | 5 Years |
FS QSFP28-SR4-100G Compatible LINK-PP LQ-M85100-SR4C 100GBASE-SR4 QSFP28 Optical Transceiver 850nm 100m MTP/MPO-12 for Data Center Spine-Leaf Networks
The LINK-PP LQ-M85100-SR4C is a high-performance, FS QSFP28-SR4-100G compatible 100GBASE-SR4 optical transceiver engineered for high-density 100G Ethernet interconnects, Top-of-Rack (ToR) to spine aggregation, and High-Performance Computing (HPC) environments. Operating over multi-mode fiber (MMF), this hot-pluggable QSFP28 module utilizes parallel optics to deliver massive bandwidth with minimal latency.
Integrating four independent transmission and receiving lanes—each operating at 25.78Gbps—this transceiver provides an aggregate data rate of 100Gbps. Built with an advanced 850nm VCSEL array, PIN photodiode detectors, and integrated Clock and Data Recovery (CDR) on both the TX and RX channels, it ensures pristine signal integrity up to 70m on OM3 and 100m on OM4 fiber. Fully compliant with IEEE 802.3bm and QSFP28 MSA standards, it offers network architects a reliable, cost-effective alternative to OEM optics without compromising enterprise-grade performance.
Application Topologies and Deployment Scenarios
The migration to 100G infrastructure relies heavily on short-reach parallel optics. This QSFP28-SR4 module is strictly optimized for intra-rack and inter-rack connectivity within large-scale hyperscale data centers and enterprise server farms.
100G Spine-to-Leaf Switch Aggregation
In modern Clos network architectures (leaf-spine), non-blocking bandwidth is critical. This module is standardly deployed as the primary high-speed interconnect bridging 100G spine switches to 100G access/leaf switches across adjacent server rows. It ensures deterministic performance for east-west traffic flows, heavily utilized in virtualization and cloud deployments.
100G to 4x 25G Breakout Connectivity
One of the most valuable use cases for the SR4 parallel optic is port density optimization via breakout cabling. By utilizing an MTP/MPO to 4x Duplex LC breakout cable, a single 100G switch port can be split into four independent 25G links. This allows a ToR switch to directly connect to four separate 25G-enabled servers or NICs (Network Interface Cards), dramatically reducing switch port costs and rack space.
High-Performance Computing (HPC) and AI Clusters
For AI training clusters and Hadoop/Big Data analytics environments requiring immense I/O throughput and microsecond latency, the 100GBASE-SR4 provides the ultra-wide pipeline necessary to prevent compute node bottlenecks over short optical paths.
Physical Layer Design and Optical Performance Optimization
Pushing 100Gbps over multi-mode fiber requires sophisticated lane synchronization and jitter management. LINK-PP transceivers are engineered with premium optical engines to guarantee a zero-packet-loss physical layer.
Parallel VCSEL Array and MTP/MPO Architecture
Unlike serial optics (which use WDM over LC duplex), the SR4 module uses a 12-fiber MTP/MPO connector. It transmits data over 4 parallel fibers (TX) and receives over 4 parallel fibers (RX), leaving the middle 4 fibers unused. The transmission core utilizes a highly reliable 850nm VCSEL (Vertical-Cavity Surface-Emitting Laser) array paired with a matched PIN detector array for optical-to-electrical conversion.
Built-in CDR and Signal Integrity
At 25.78Gbps per lane, electrical jitter and chromatic dispersion can severely degrade the optical eye diagram. This module features Built-in Clock and Data Recovery (CDR) circuits on both the TX and RX paths. The CDR resets the signal timing, effectively cleaning up jitter and guaranteeing strict IEEE 802.3bm eye mask compliance before transmission and after reception.
Low Power Consumption and Thermal Management
High-density 100G line cards are highly sensitive to thermal overload. This QSFP28 transceiver is engineered for exceptional power efficiency, consuming ≤3.3W max. Combined with a premium die-cast thermal housing, it ensures stable 0°C to 70°C commercial operation without forcing switch chassis fans into overdrive.
Multi-Vendor Compatibility and DOM/DDM Diagnostics
Data center operators require optics that drop seamlessly into existing white-box or branded OEM environments while providing deep granular visibility into all four parallel optical lanes.
FS Compatibility and Switch Validation
Undergoing rigorous EEPROM coding and validation, the LQ-M85100-SR4C is natively recognized as an FS QSFP28-SR4-100G module. It ensures immediate plug-and-play operation in switches originally populated with FS optics, as well as universal MSA-compliant platforms (such as Arista, Edgecore, and generic white-box switches) without triggering "unsupported transceiver" lock-outs.
Real-Time I2C Digital Diagnostic Monitoring
Fully compliant with the SFF-8636 management interface, this transceiver provides real-time DOM/DDM telemetry via the switch's I2C bus. Network engineers can utilize CLI or SNMP to actively monitor Transceiver Temperature, Vcc Supply Voltage, and crucially, the independent TX Bias Current, TX Optical Power, and RX Optical Power for all four individual lanes.
Optical Link Health and Preventive Maintenance
Monitoring lane-specific RX power is critical in parallel optics. If one of the four RX lanes shows significant degradation, it immediately indicates dust or debris on a specific fiber within the MPO array, allowing engineers to clean the connector proactively before a single-lane failure brings down the entire 100G logical link.
Selection Guide and Deployment Considerations
Deploying parallel 100G optics introduces unique cabling and configuration challenges not present in standard 10G/25G duplex links. Follow these critical guidelines to ensure a flawless deployment.
The Host RS-FEC Requirement (Crucial)
This optical module does not have inbuilt FEC (Forward Error Correction) on the chip, which is the standard architectural design for 100GBASE-SR4. Therefore, to achieve a zero-error 100m link, RS-FEC (Reed-Solomon FEC, Clause 91) MUST be enabled on the host switch port. If host FEC is disabled, the link will experience high Bit Error Rates (BER) and packet drops.
MTP/MPO Cabling Polarity and Pinning
SR4 transceiver receptacles are always Unpinned (Female). To physically connect to this module, your MTP/MPO fiber patch cable MUST be Pinned (Male). Furthermore, to connect two switches directly (100G to 100G), you must use a Type B (Cross-Over) MTP/MPO-12 cable to ensure TX lanes align correctly with RX lanes.
Distance Limits and Fiber Types
To achieve the rated 100Gbps transmission distance, your physical cabling must meet the following parameters:
- OM4 Multimode Fiber: Up to 100 meters (with Host FEC enabled)
- OM3 Multimode Fiber: Up to 70 meters (with Host FEC enabled)
- Connector Type: MTP/MPO-12 (PC or UPC polish - absolutely NO APC green connectors, as MMF MTPs are flat-polished)
Common Deployment Mistakes in 100G SR4 Networks
Avoid these frequent engineering errors to ensure a successful 100G deployment:
- MPO Contamination: MTP/MPO connectors have a massive surface area compared to LC connectors. Dust is the #1 cause of SR4 link failures. Always inspect and use an MPO one-click cleaner before inserting the cable.
- Incorrect Breakout Cables: When doing a 100G to 4x25G breakout, ensure you order an MTP-12 to 4x LC Duplex breakout cable mapped to the SR4 standard (utilizing outer fibers 1-4 and 9-12).
- Mixing MTP APC and UPC: Attempting to insert a green MTP-APC (angled) cable into an SR4 module will physically crush the transceiver's internal lens array.
Packaging, Shipping and Global Delivery for Networking Products
Anti-static packaging, shock-resistant protection, fast order dispatch, and reliable worldwide delivery for all LINK-PP networking products.
Anti-Static Protective Packaging
Protect networking products from electrostatic discharge and handling-related damage.
Shock-Resistant Transport Protection
Protect products against physical impacts during storage and international transportation.
Fast Order Processing and Dispatch
Accelerate order handling to ensure quick warehouse deployment.
Global Logistics and International Delivery
Ship products efficiently to customers across worldwide locations.
100G QSFP28 Technical Support and Deployment Assistance
LINK-PP provides expert technical support, from product selection and compatibility verification to deployment and long-term operation.
Pre-Sales Technical Consultation
Technical consultation to help you verify QSFP28-SR4-100G compatibility and select the appropriate product for your application.
Compatibility Verification Support
Verification support to help ensure compatibility with your equipment, applications, and deployment requirements.
Deployment & Installation Assistance
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Long-Term Technical Assurance
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
Industry Standards, Compliance and Quality Assurance
LINK-PP products are manufactured under recognized quality management systems and designed to support applicable industry standards, regulatory compliance, and long-term deployment requirements, including IEEE 802.3, RoHS, REACH, ISO 9001, and ISO 14001 where applicable. 「View Quality & Compliance Center」
ISO 9001 Quality Management
Manufactured under certified quality management processes to ensure consistent product quality and production control.
IEEE 802.3 Standards Compliance
Designed in accordance with applicable networking and Ethernet standards, including IEEE specifications where relevant.
RoHS Compliance
Manufactured using materials that support restrictions on hazardous substances for global market requirements.
REACH Compliance
Material declarations and supply chain processes support applicable REACH regulatory requirements.
Product Safety Assurance
Selected products support recognized safety and reliability requirements for networking applications.
Reliability Verification Testing
Products undergo verification and quality testing to support stable operation in enterprise, telecom, and industrial environments.
100G QSFP28 Warranty and After-Sales Service
LINK-PP provides warranty coverage and after-sales support to help ensure stable operation and long-term product performance.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
Keyword:
SFP Download
Product Drawing
FS Compatible 100G QSFP28-SR4-100G FAQ
Recommend
-
Nav Menu
-
About LINK-PP
-
All Products
-
Applications