LQ-M85100-SR4C 100GBASE SR4 QSFP28 100m 850nm OM4 DOM MPO-12 Parallel MMF Optical Transceiver Module
P/N:
LQ-M85100-SR4C
Manufacturer:
LINK-PP
Compatible Brand:
LINK-PP
Compatible P/N:
LQ-M85100-SR4C
- Compatible Brands: LINK-PP
- Form Factor: QSFP28
- Data Rate: 100G
- Distance: ≤100m
- Type: Multimode
- Connector: MTP/MPO-12
- Model: SR4
- Wavelength: 850nm
- P/N: LQ-M85100-SR4C
- Manufacture: LINK-PP
- Compatible Brand: LINK-PP
- Compatible P/N: LQ-M85100-SR4C
Optical Transceivers & SFP/QSFP Cages Solutions
- Optical transceivers: SFP / SFP+ / SFP28 / QSFP+ / QSFP28 / QSFP-DD / OSFP
- SFP cages & QSFP cages for high-density switch design
- High-speed optical connector and receptacle structures
- Mechanical + thermal + EMI optimization for optical interfaces
- Designed for 10G / 100G / 200G / 400G / 800G data center networks
Ethernet Connectivity & High-Speed Interface Solutions
- Integrated RJ45 MagJack connectors for high-speed Ethernet
- Modular Jack solutions for scalable network port design
- High-performance LAN transformer integration
- Support for 1G / 2.5G / 5G / 10G Ethernet applications
Signal Integrity & Network Reliability Engineering
- LAN transformers for signal isolation and impedance matching
- PoE and high-speed Ethernet magnetic components
- EMI/EMC optimization for network stability
- Designed for hyperscale data centers and telecom systems
Product Specifications
| LINK-PP Part Number | LQ-M85100-SR4C | Vendor Name | LINK-PP |
| Form Factor | QSFP28 | Max Data Rate | 100Gbps |
| Wavelength | 850nm | Max Cable Distance | 70m@OM3/100m@OM4 |
| Connector | MTP/MPO-12 | Media | MMF |
| Transmitter Type | VCSEL 850nm | Receiver Type | PIN |
| Power Consumption | ≤3.3W | Extinction Ratio | >3dB |
| DDM/DOM | Supported | Case Temperature range | 0°C to +70°C |
| TX Power | -8.4~2.4dBm | Minimum Receiver Power | -10.3dBm |
| Powerbudget | 1.9dB | Receiver Overload | 2.4dBm |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR | Inbuilt FEC | No |
| Protocols | IEEE 802.3bm, QSFP28 MSA, SFF-8665, SFF-8636, RoHS, CPRI, eCPRI | Warranty | 5 Years |
LINK-PP LQ-M85100-SR4C 100GBASE-SR4 QSFP28 MTP/MPO MMF Optical Transceiver Technical Overview
The LINK-PP LQ-M85100-SR4C is a high-performance 100GBASE-SR4 QSFP28 optical transceiver module delivering 100 Gbps aggregate bandwidth over multi-mode fiber (MMF) up to 70 meters on OM3 or 100 meters on OM4 with Host RS-FEC via an MTP/MPO-12 connector. Integrating a 4-channel 850nm VCSEL laser transmitter array, a PIN photodiode receiver, internal TX/RX Clock and Data Recovery (CDR) retimers, and an SFF-8636 compliant Digital Optical Monitoring (DOM) interface, it provides an energy-efficient (≤3.3W) short-reach interconnect solution backed by a 5-Year Warranty.
- 4-Lane Parallel 100G Optical Engine: Transmits 100 Gbps aggregate throughput across 4 independent 25.78125 Gbps NRZ lanes over 8 multi-mode fibers using a 12-fiber MTP/MPO interface.
- Built-In TX & RX Clock and Data Recovery (CDR): Integrated retimers on both transmit and receive paths clean up high-frequency electrical jitter, ensuring pristine optical eye diagrams and ultra-low bit error rates.
- Optimized Energy Efficiency (≤3.3W): Low power consumption profile protects switch port thermal density, reducing cooling overhead in high-density 100G data center switch chassis.
- Multi-Vendor QSFP28 MSA Compliance: Fully compliant with IEEE 802.3bm 100GBASE-SR4, SFF-8665, SFF-8636, CPRI, and eCPRI specifications, pre-coded for Cisco, Arista, Juniper, Dell, FS.com, and generic 100G ports.
LINK-PP LQ-M85100-SR4C 100GBASE-SR4 QSFP28 Optical Transceiver Overview
LINK-PP LQ-M85100-SR4C is a hot-pluggable 100Gbps QSFP28 optical transceiver module engineered for short-reach multi-mode fiber interconnects in enterprise data centers and cloud computing networks. Featuring four 850nm VCSEL laser channels, a PIN photodiode receiver, MTP/MPO-12 optical interfaces, and full Digital Optical Monitoring (DOM) capabilities, this module delivers robust signal integrity over short distances (70m OM3 / 100m OM4 with Host RS-FEC). Pre-programmed for seamless interoperability across industry-standard 100G hardware, it serves as a fully qualified, cost-effective replacement for Cisco QSFP-100G-SR4-S and generic 100GBASE-SR4 OEM transceivers.
Key Benefits of LINK-PP LQ-M85100-SR4C 100GBASE-SR4 QSFP28 Optical Transceiver
- Full 100G Aggregate Bandwidth over Short-Reach Multi-Mode Fiber: Delivers 100 Gbps parallel data transmission over OM3 (up to 70m) or OM4 (up to 100m) MMF trunks, ideal for intra-rack and Top-of-Rack (ToR) switch links.
- Built-In Transmit & Receive CDR Retimers: Dual-direction CDR circuits retime incoming electrical signals per 25G lane, compensating for host board trace losses and eliminating jitter propagation.
- Low Power Consumption (≤3.3W) for High-Density Switches: Draws ≤3.3W max under full load, preventing thermal throttling in densely populated 32-port 1U 100G switch line cards.
- SFF-8636 Compliant Per-Lane DOM Telemetry: Features real-time optical diagnostics providing granular lane-by-lane visibility into transmitter bias currents, optical input power, output power, and module temperature.
- Hot-Pluggable QSFP28 MSA Form Factor: Easily inserted or removed from active 100G QSFP28 switch ports without powering down host equipment or disrupting adjacent network traffic.
- Multi-Vendor Switch Interoperability Backed by 5-Year Warranty: Pre-programmed EEPROM firmware guarantees error-free recognition in Cisco, Arista, Juniper, Dell, FS.com, and generic 100G switches.
100GBASE-SR4 Parallel Optics & CDR Architecture
The LINK-PP LQ-M85100-SR4C operates under the 100GBASE-SR4 protocol defined in IEEE 802.3bm and SFF-8665 QSFP28 MSA specifications, utilizing 4 parallel 25.78125 Gbps NRZ lanes to achieve 100 Gbps aggregate bandwidth.
850nm VCSEL Array & 4-Lane Parallel Transmission
The electro-optic engine incorporates a 4-channel 850nm Vertical-Cavity Surface-Emitting Laser (VCSEL) array operating with an average TX power between -8.4 dBm and +2.4 dBm. On the receive side, four PIN photodiodes with TIA preamplifiers provide a minimum receiver power sensitivity of -10.3 dBm and a 2.4 dBm overload threshold. Internal CDR circuits retime both TX and RX 25G channels, ensuring clean eye diagrams over MTP/MPO-12 multi-mode ribbon cables when paired with Host Reed-Solomon Forward Error Correction (RS-FEC 528,514).
SFF-8636 Digital Optical Monitoring (DOM) Diagnostics
Utilizing a 2-wire I2C serial interface mapped per SFF-8636 standards, the transceiver provides digital optical telemetry. Network operations engineers can query real-time optical parameters per channel—including RX input power in dBm and TX bias currents—allowing proactive link budget tracking and rapid fault isolation.
Switch Interoperability & ≤3.3W Thermal Efficiency
High thermal density in 100G data center switches demands strict module power budget control. The LQ-M85100-SR4C addresses this through energy-efficient IC driver design.
≤3.3W Power Dissipation & Plug-and-Play EEPROM
Operating at ≤3.3W max per port, the LQ-M85100-SR4C prevents heat accumulation in switch line cards. Pre-programmed with accurate vendor EEPROM data maps, it passes host optical verification in Cisco, Arista, Juniper, and Dell switches without manual CLI overrides or throwing vendor-lock alarms.
Target Applications: Data Center Spine-Leaf, ToR Uplinks, and High-Density SANs
Combining 100Gbps aggregate bandwidth, short-reach MMF capability, SFF-8636 DOM telemetry, and QSFP28 MSA compliance, the LINK-PP LQ-M85100-SR4C supports critical optical infrastructure:
- Data Center Spine-Leaf & Top-of-Rack (ToR) Interconnects: Ideal for high-density 100GbE inter-rack server connections and leaf-to-spine switch uplinks over MTP/MPO OM3/OM4 cabling.
- Enterprise Core Switch 100GbE Short-Reach Backbones: Deployed in enterprise data centers for high-speed short-distance switch-to-switch links within the same rack row.
- High-Performance Compute (HPC) Clusters & Storage Area Networks: Suitable for supercomputing clusters, NVMe-over-Fabrics storage arrays, and high-bandwidth interconnects.
How to Select and Verify LQ-M85100-SR4C vs. Cisco QSFP-100G-SR4-S
Network engineers and procurement specialists evaluating the LINK-PP LQ-M85100-SR4C as a secondary-source alternative for Cisco QSFP-100G-SR4-S or generic 100GBASE-SR4 optics should verify the following core parameters:
- Optical Cable & Connector Matching: Confirm that your installed optical fiber infrastructure uses 12-fiber MTP/MPO (Female, Type B polarity) multi-mode cables (OM3 or OM4), as 100GBASE-SR4 is incompatible with single-mode fiber or duplex LC cables.
- Host RS-FEC Requirement for 100m Reach: Ensure that your host switch port has Reed-Solomon Forward Error Correction (RS-FEC per IEEE 802.3bm) enabled to achieve full 100m reach on OM4 MMF.
- Per-Lane DOM Telemetry Verification: Verify multi-channel optical power levels via switch CLI commands such as `show interfaces transceiver` to inspect individual 25G channel launch and receive power levels.
- Power Consumption Budget & Warranty: Confirm that host switch port thermal budgets accommodate ≤3.3W per QSFP28 slot, and verify the 5-Year replacement warranty.
Frequently Asked Questions
What is LINK-PP LQ-M85100-SR4C?
LINK-PP LQ-M85100-SR4C is a 100Gbps 100GBASE-SR4 QSFP28 optical transceiver module operating at 850nm over multi-mode fiber (MMF) up to 70m on OM3 or 100m on OM4 via an MTP/MPO-12 connector with built-in CDR and DOM support.
What cable type and maximum distance are supported by LQ-M85100-SR4C?
The module operates over multi-mode fiber (MMF 50/125µm) using an MTP/MPO-12 connector, supporting maximum link distances up to 70 meters on OM3 fiber or 100 meters on OM4 fiber with Host RS-FEC enabled.
Does LINK-PP LQ-M85100-SR4C require Host FEC?
Yes. Per IEEE 802.3bm 100GBASE-SR4 specifications, the module relies on Host Reed-Solomon Forward Error Correction (RS-FEC) enabled on the switch port to achieve full 100m distance on OM4 MMF.
Does LQ-M85100-SR4C support DDM/DOM optical diagnostics?
Yes. The module features full DDM / DOM diagnostic support per SFF-8636, providing real-time telemetry monitoring for TX power, RX power, bias current, supply voltage, and internal temperature across all four 25G channels.
What is the maximum power consumption of LQ-M85100-SR4C?
The module features an energy-efficient power draw rated at ≤3.3W max, ensuring cool operation and thermal compatibility with dense 100G QSFP28 switch chassis.
What warranty is provided with the LINK-PP LQ-M85100-SR4C transceiver?
The LINK-PP LQ-M85100-SR4C transceiver is backed by a 5-Year replacement warranty, ensuring long-term operational reliability in enterprise and cloud data center environments.
Packaging, Shipping and Global Delivery for Networking Products
Anti-static packaging, shock-resistant protection, fast order dispatch, and reliable worldwide delivery for all LINK-PP networking products.
Anti-Static Protective Packaging
Protect networking products from electrostatic discharge and handling-related damage.
Shock-Resistant Transport Protection
Protect products against physical impacts during storage and international transportation.
Fast Order Processing and Dispatch
Accelerate order handling to ensure quick warehouse deployment.
Global Logistics and International Delivery
Ship products efficiently to customers across worldwide locations.
100G QSFP28 Technical Support and Deployment Assistance
LINK-PP provides expert technical support, from product selection and compatibility verification to deployment and long-term operation.
Pre-Sales Technical Consultation
Technical consultation to help you verify LQ-M85100-SR4C compatibility and select the appropriate product for your application.
Compatibility Verification Support
Verification support to help ensure compatibility with your equipment, applications, and deployment requirements.
Deployment & Installation Assistance
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Long-Term Technical Assurance
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
Industry Standards, Compliance and Quality Assurance
LINK-PP products are manufactured under recognized quality management systems and designed to support applicable industry standards, regulatory compliance, and long-term deployment requirements, including IEEE 802.3, RoHS, REACH, ISO 9001, and ISO 14001 where applicable.
ISO 9001 Quality Management
Manufactured under certified quality management processes to ensure consistent product quality and production control.
IEEE 802.3 Standards Compliance
Designed in accordance with applicable networking and Ethernet standards, including IEEE specifications where relevant.
RoHS Compliance
Manufactured using materials that support restrictions on hazardous substances for global market requirements.
REACH Compliance
Material declarations and supply chain processes support applicable REACH regulatory requirements.
Product Safety Assurance
Selected products support recognized safety and reliability requirements for networking applications.
Reliability Verification Testing
Products undergo verification and quality testing to support stable operation in enterprise, telecom, and industrial environments.
100G QSFP28 Warranty and After-Sales Service
LINK-PP provides warranty coverage and after-sales support to help ensure stable operation and long-term product performance.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
SFP Download
Product Drawing
LINK-PP Compatible 100G LQ-M85100-SR4C FAQ
Recommend
-
Nav Menu
-
About LINK-PP
-
All Products
-
Applications