HOT CROSS-REFERENCE SEARCHES All Products
HR911105A Cisco GLC-LH-SMD Pulse J1011F21PNL LPJG0926HENL TE 2170704-1 SFP-10G-SR
POPULAR CATEGORIES
Matched Parts (Real-time ES) Use ↑ ↓ to select, Enter to open
+
  • LS-MM8516-S1C-1.webp
  • LS-MM8516-S1C-2.webp
  • LS-MM8516-S1C-3.webp
  • LS-MM8516-S1C-4.webp
  • LS-MM8516-S1C-5.webp

Dell TDTCP Compatible 16G Fibre Channel SFP+ Optical Transceiver with DOM for SAN Storage Networks

P/N:

LS-MM8516-S1C

Manufacturer:

LINK-PP

Classification:

Compatible Brand:

DELL

Compatible P/N:

TDTCP

  • Compatible Brands: DELL
  • Form Factor: SFP+
  • Data Rate: 10G
  • Distance: ≤100m
  • Type: Multimode
  • Connector: Simplex LC
  • Wavelength: 850nm
  • P/N: LS-MM8516-S1C
  • Manufacture: LINK-PP
  • Compatible Brand: DELL
  • Compatible P/N: TDTCP

Product Specifications

LINK-PP Part Number LS-MM8516-S1C Dell Part Number TDTCP
Part Status Active Form Factor SFP+
Max Data Rate 14.025 Gbps Wavelength 850nm
Max Cable Distance 100m@OM3 Connector Duplex LC
Media MMF Transmitter Type VCSEL
Receiver Type PIN Commercial Temperature Range 0 to 70°C
TX Power -7.8-0.5dBm Receiver Sensitivity < -10.5dBm
Receiver Overload 0.5dBm RX Power -16-0.5dBm
DOM Support Yes Protocols FC-PI-5, SFF-8432, SFF-8472, SFF-8431

Dell TDTCP Compatible LINK-PP LS-MM8516-S1C 16G Fibre Channel SFP+ SW Optical Transceiver 850nm 100m Duplex LC for SAN Storage Networks

The LINK-PP LS-MM8516-S1C is a high-performance, Dell TDTCP compatible 16G Fibre Channel (16GFC) SFP+ Short Wave (SW) optical transceiver engineered for high-speed Storage Area Networks (SAN), data center storage fabrics, and all-flash array interconnects.

Built with an advanced 850nm VCSEL laser, a high-sensitivity PIN receiver, and fully compliant with FC-PI-5 and SFF-8431 standards, this module delivers predictable 14.025Gbps optical performance with backward compatibility for 8G and 4G FC. Featuring built-in Digital Diagnostic Monitoring (DOM/DDM) compliant with SFF-8472, it provides storage administrators with real-time telemetry data to ensure zero-packet-loss transmission and strict signal integrity across complex storage infrastructures.

Application Topologies and Deployment Scenarios

Understanding where and how 16G SFP+ SW optics fit into your storage architecture is critical for eliminating I/O bottlenecks. This transceiver is strictly optimized for low-latency, loss-less data transmission within data center storage racks and adjacent rows.

Storage Area Network (SAN) Core and Edge Switching

In modern high-density SAN environments, 16G FC optical transceivers are commonly deployed in director-class switches and edge switches to support massive block-level data transfers. Typical engineering applications include interconnecting SAN switches to build highly available storage fabrics that require deterministic performance and microsecond latency.

Server HBA to Storage Array Connectivity

This module is widely utilized to establish direct, high-speed links between enterprise servers equipped with 16G Host Bus Adapters (HBAs) and centralized storage systems. It ensures bottleneck-free I/O performance for mission-critical applications running on All-Flash Arrays (AFA), NVMe storage over Fibre Channel (NVMe/FC), and heavy database workloads.

Data Center Storage Fabric Upgrades

With its auto-negotiation capabilities (typically supporting 14.025Gbps, 8.5Gbps, and 4.25Gbps depending on switch configuration), this transceiver provides a seamless upgrade path for legacy 4G/8G SAN infrastructures, allowing enterprises to scale their storage bandwidth without completely overhauling their fiber cabling plant.

Physical Layer Design and Optical Performance Optimization

Storage traffic is highly sensitive to frame drops. The reliability of a 16G optical link relies fundamentally on the quality of its internal optical engine. LINK-PP transceivers are engineered to exceed standard Fibre Channel requirements, ensuring robust signal integrity under heavy storage I/O loads.

Optical Transmitter and Receiver Architecture

The transmission core utilizes a highly reliable 850nm VCSEL (Vertical-Cavity Surface-Emitting Laser). On the receiving end, a low-dark-current PIN photodiode ensures excellent optical-to-electrical conversion. This matched TOSA/ROSA architecture minimizes jitter and guarantees a clean eye diagram for 14.025Gbps serial transmission.

Signal Integrity and Link Budget Engineering

The optical link budget determines whether a transceiver can maintain stable communication across different patch panel losses in a SAN environment. This LS-MM8516-S1C module is strictly engineered to deliver:

  • Tx Output Power: -7.8 dBm to 0.5 dBm
  • Rx Sensitivity: Better than -10.5 dBm
  • Receiver Overload: 0.5 dBm
  • Max Data Rate: 14.025Gbps

This optimized optical budget provides sufficient margin to accommodate typical insertion losses from LC connectors and MTP/MPO breakout cassettes without compromising data integrity.

Thermal Management and Reliability Optimization

Designed with a premium die-cast metal housing, this hot-pluggable transceiver ensures superior EMI shielding and thermal management. Operating efficiently on a single +3.3V power supply, it remains thermally stable across commercial operating temperatures (0°C to 70°C) and complies strictly with RoHS environmental standards.

Multi-Vendor Compatibility and DOM/DDM Diagnostics

Storage administrators require optics that operate seamlessly within proprietary SAN ecosystems while providing granular visibility into link health to prevent unexpected storage disconnections.

Switch and Storage Compatibility Validation

LINK-PP modules undergo rigorous EEPROM coding and hardware validation. The LS-MM8516-S1C is natively recognized as a Dell TDTCP compatible module, ensuring plug-and-play deployment in Dell EMC Connectrix switches, PowerVault storage, and compatible Brocade or Cisco MDS Fibre Channel networking platforms without triggering vendor lock-out errors.

Real-Time Digital Diagnostic Monitoring (DOM/DDM)

Equipped with Real-Time Digital Diagnostic Monitoring (compliant with SFF-8472), this transceiver provides real-time access to critical physical layer metrics. SAN administrators can actively monitor core parameters including Transceiver Temperature, +3.3V Supply Voltage, Laser Bias Current, Transmitted (Tx) Power, and Received (Rx) Power.

Optical Link Health and Preventive Maintenance

By leveraging DOM telemetry, IT operations can transition from reactive storage troubleshooting to proactive maintenance. Monitoring Rx power degradation helps identify dirty fiber end-faces, which is critical since 16G Fibre Channel is highly sensitive to optical return loss and reflection.

Selection Guide and Deployment Considerations

Choosing the correct Fibre Channel optical transceiver is critical for SAN stability. Below are essential deployment guidelines to ensure optimal performance.

Choosing Between Short Wave (SW) and Long Wave (LW) Optics

Select this Short Wave (SW) 850nm module for intra-building or intra-rack storage connections using Multimode Fiber (MMF). For longer campus or cross-data-center SAN extensions (up to 10km), a 1310nm Long Wave (LW) Single-Mode transceiver is required.

Fiber Type and Distance Matching

To achieve the maximum 14.025Gbps rated distance, ensure your physical cabling infrastructure matches the transceiver specifications:

  • OM3 Multimode Fiber: Up to 100 meters (Recommended baseline)
  • OM2 Multimode Fiber: Up to 35 meters (Legacy environments)
  • Connector Type: Duplex LC (Ensure UPC polish, do not use APC green connectors)

Common Deployment Mistakes in SAN Environments

To ensure a successful SAN installation, network technicians should avoid these frequent deployment errors:

  • Mixing SMF and MMF: Using Single-Mode Fiber patch cords with this SW (Multimode) transceiver causes immediate massive signal attenuation and link failure.
  • Dirty LC Connectors: Dust on an 850nm VCSEL laser is the leading cause of low Rx power and CRC errors in Fibre Channel networks. Always inspect and clean before insertion.
  • Speed Mismatches: Forcing a 16G port to connect to an older 2G device (most 16G optics only step down to 8G and 4G).

Packaging, Shipping and Global Delivery for Networking Products

Anti-static packaging, shock-resistant protection, fast order dispatch, and reliable worldwide delivery for all LINK-PP networking products.

Anti-Static Protective Packaging

Anti-Static Protective Packaging

Protect networking products from electrostatic discharge and handling-related damage.

Shock-Resistant Transport Protection

Shock-Resistant Transport Protection

Protect products against physical impacts during storage and international transportation.

Fast Order Processing and Dispatch

Fast Order Processing and Dispatch

Accelerate order handling to ensure quick warehouse deployment.

Global Logistics and International Delivery

Global Logistics and International Delivery

Ship products efficiently to customers across worldwide locations.

10G SFP+ Technical Support and Deployment Assistance

LINK-PP provides expert technical support, from product selection and compatibility verification to deployment and long-term operation.

Pre-Sales Technical Consultation

Pre-Sales Technical Consultation

Technical consultation to help you verify TDTCP compatibility and select the appropriate product for your application.

Compatibility Verification Support

Compatibility Verification Support

Verification support to help ensure compatibility with your equipment, applications, and deployment requirements.

Deployment & Installation Assistance

Deployment & Installation Assistance

Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.

Long-Term Technical Assurance

Long-Term Technical Assurance

Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.

Industry Standards, Compliance and Quality Assurance

LINK-PP products are manufactured under recognized quality management systems and designed to support applicable industry standards, regulatory compliance, and long-term deployment requirements, including IEEE 802.3, RoHS, REACH, ISO 9001, and ISO 14001 where applicable. 「View Quality & Compliance Center」

ISO 9001 Quality Management System Certification

ISO 9001 Quality Management

Manufactured under certified quality management processes to ensure consistent product quality and production control.

IEEE 802.3 Ethernet Standard Compliance

IEEE 802.3 Standards Compliance

Designed in accordance with applicable networking and Ethernet standards, including IEEE specifications where relevant.

RoHS Compliance

RoHS Compliance

Manufactured using materials that support restrictions on hazardous substances for global market requirements.

REACH Compliance

REACH Compliance

Material declarations and supply chain processes support applicable REACH regulatory requirements.

Product Safety Assurance

Product Safety Assurance

Selected products support recognized safety and reliability requirements for networking applications.

Reliability Verification Testing

Reliability Verification Testing

Products undergo verification and quality testing to support stable operation in enterprise, telecom, and industrial environments.

10G SFP+ Warranty and After-Sales Service

LINK-PP provides warranty coverage and after-sales support to help ensure stable operation and long-term product performance.

15 days

15-day no-reason return and refund

Free maintenance or replacement

Free replacement for dead-on-arrival (DOA) or defective items within the initial period

Free maintenance

Free repair services for manufacturing defects throughout the warranty period

Limitations

Warranty exclusions and conditions apply

Keyword:

SFP Download