Juniper EX-SFP-10GE-BX54-100 Compatible 10GBASE-BX SFP+ BiDi Optical Transceiver with DOM
P/N:
LS-BL554910-A0C
Manufacturer:
LINK-PP
Compatible Brand:
Juniper
Compatible P/N:
EX-SFP-10GE-BX54-100
- Compatible Brands: Juniper
- Form Factor: SFP+
- Data Rate: 10G
- Distance: ≤100km
- Type: Single Mode
- Connector: Simplex LC
- Wavelength: 1550nm-TX/1490nm-RX
- P/N: LS-BL554910-A0C
- Manufacture: LINK-PP
- Compatible Brand: Juniper
- Compatible P/N: EX-SFP-10GE-BX54-100
Product Specifications
| LINK-PP Part Number | LS-BL554910-A0C | Juniper Part Number | EX-SFP-10GE-BX54-100 |
| Form Factor | SFP+ | Max Data Rate | 10.7 Gbps |
| Wavelength | 1550nm-TX / 1490nm-RX | Max Cable Distance | 100km |
| Connector | Simplex LC | Media | SMF (Single-Mode Fiber) |
| Optical Components | Cooled EML / APD BiDi | DOM / DDM Support | Yes |
| TX Power | -1.0 to +5.0 dBm | RX Power | -23.0 to -6.0 dBm |
| Receiver Sensitivity | ≤ -25.0 dBm | Receiver Overload | -7.0 dBm |
| Operating Case Temperature | 0°C to 70°C | Protocols | SFP+ MSA Compliant, CPRI, eCPRI |
Juniper EX-SFP-10GE-BX54-100 Compatible LINK-PP LS-BL554910-A0C 10G BiDi SFP+ Optical Transceiver 1550nm-TX/1490nm-RX 100km Simplex LC for Extended Metro Networks
The LINK-PP LS-BL554910-A0C is a high-performance, Juniper EX-SFP-10GE-BX54-100 compatible 10G Bidirectional (BiDi) SFP+ optical transceiver engineered for ultra-long-haul Metropolitan Area Networks (MAN), extended enterprise campus links, and 5G fronthaul connectivity. Designed to transmit and receive 10Gbps payload over a single strand of Single-Mode Fiber (SMF) via Wavelength Division Multiplexing (WDM), this module effectively doubles the capacity of your existing fiber plant.
Built with a premium Cooled EML laser transmitter and a highly sensitive APD photodiode integrated with a trans-impedance preamplifier (TIA), this module delivers deterministic 10.7Gbps performance up to 100 kilometers. Fully compliant with SFP+ MSA, CPRI, and eCPRI standards, it provides network operations centers (NOC) with real-time DOM telemetry to ensure uninterrupted connectivity across critical long-haul Juniper routing and switching infrastructures.
Application Topologies and Deployment Scenarios
Understanding the strategic value of 100km BiDi optical technology is crucial for optimizing CAPEX in telecom and enterprise networks. This transceiver is strictly optimized for environments where fiber strand availability is limited and bridging massive physical distances without inline amplification is required.
Metropolitan Area Networks (MAN) and ISP Backbones
For ISPs and regional carriers, bridging distances between metropolitan POPs (Points of Presence) requires high optical budgets. This 100km-rated transceiver allows architects to establish edge-to-core network designs that completely bypass intermediate optical amplifiers or active repeaters, dramatically simplifying the transmission topology and reducing points of failure.
Extended Enterprise Campus and Inter-Branch Links
In large-scale enterprise, government, or university deployments utilizing Juniper EX series switches, this module provides seamless 10G backbone connectivity across geographically dispersed facilities. It enables high-speed disaster recovery (DR) synchronization and centralized data center access over dark fiber connections spanning up to 100km.
Fiber Resource Optimization via BiDi WDM
In legacy deployments utilizing standard dual-fiber transceivers (LR/ER/ZR), scaling network capacity requires trenching new fiber—a massively expensive undertaking. By utilizing integrated WDM technology to multiplex TX and RX over a single Simplex LC strand, network engineers can instantly double their available fiber capacity without laying new cables.
Physical Layer Design and Optical Performance Optimization
Transmitting 10Gbps over 100 kilometers requires sophisticated optical engineering to overcome chromatic dispersion and severe signal attenuation. LINK-PP transceivers are built with superior chip-level components to ensure robust link integrity.
Cooled EML Transmitter and APD Receiver Architecture
The transmission core utilizes a Cooled EML (Electro-absorption Modulated Laser) operating at 1550nm, which offers significantly lower chirp and narrower spectral width than standard DML lasers, preventing data corruption over ultra-long distances. The receiving end employs a highly sensitive 1490nm APD (Avalanche Photodiode), capable of amplifying extremely weak optical signals after 100km of fiber attenuation.
Signal Integrity and 100km Optical Link Budget
The optical link budget is the critical metric for long-haul stability. This LS-BL554910-A0C module boasts an exceptional optical power profile engineered for substantial distance:
- Tx Output Power: -1.0 dBm to +5.0 dBm
- Rx Sensitivity: Better than -25.0 dBm
- Receiver Overload: -7.0 dBm
- Optical Link Budget: Minimum ~24 dB margin (guaranteeing 100km reach on pristine OS2 single-mode fiber)
Thermal Management and Reliability Optimization
Long-reach optics generate significant heat due to their high-power EML lasers. Designed with a premium die-cast metal housing and an integrated MCU control unit, this transceiver ensures superior thermal dissipation and EMI shielding. It operates reliably across standard commercial temperatures (0°C to 70°C), making it ideal for climate-controlled data centers, POPs, and enterprise MDF/IDF closets.
Multi-Vendor Compatibility and DOM/DDM Diagnostics
Telecom operators and enterprise IT teams require optics that integrate universally with edge switches while providing deep visibility into the physical layer across spanning distances.
Juniper EX Series and Junos OS Compatibility Validation
Undergoing stringent hardware and EEPROM validation, the LS-BL554910-A0C is natively recognized by Junos OS as a Juniper EX-SFP-10GE-BX54-100 compatible module. It bypasses proprietary vendor lock-outs, ensuring immediate plug-and-play operation in Juniper EX Series Ethernet Switches (e.g., EX4300, EX4600, EX9200) and SRX Series Services Gateways.
Real-Time Digital Diagnostic Monitoring (DOM/DDM)
Integrated DOM/DDM (compliant with SFF-8472) provides network administrators with real-time access to operational telemetry. Through Junos OS CLI (show interfaces diagnostics optics) or standard SNMP polling, NOC engineers can actively monitor Transceiver Temperature, TX Bias Current, Vcc Voltage, TX Optical Power, and RX Optical Power.
Remote Link Health and Preventive Maintenance
For long-haul deployments, dispatching a technician to troubleshoot physical links is costly. DOM telemetry allows IT teams to monitor gradual RX power degradation caused by micro-bends in aging fiber or weather-induced splice degradation, enabling proactive maintenance scheduling before a hard link failure occurs.
Selection Guide and Deployment Considerations
Deploying 100km BiDi optics involves strict adherence to physical layer rules. Below are critical engineering guidelines to prevent hardware damage and ensure optimal transmission.
BiDi Wavelength Pairing Requirement
Bidirectional transceivers must be deployed in complementary pairs. Because this module transmits at 1550nm and receives at 1490nm (1550nm-TX / 1490nm-RX), the Juniper switch at the remote end of the fiber MUST be equipped with the exact opposite transceiver model (1490nm-TX / 1550nm-RX) to establish a link.
Fiber Type and Distance Matching
To achieve the rated 10Gbps transmission distance without excessive dispersion penalties, your physical cabling must meet the following parameters:
- Fiber Standard: 9/125µm Single-Mode Fiber (OS2 is highly recommended over OS1 for 100km links)
- Connector Type: Simplex LC (UPC Polish)
- Splice Quality: Distance achievable is highly dependent on fiber attenuation (typically calculated at ≤ 0.25 dB/km at 1550nm) and the number of fusion splices in the path.
Common Deployment Mistakes in Long-Haul BiDi Networks
Avoid these frequent engineering errors to ensure a successful long-haul deployment:
- Receiver Burnout (Crucial): This module features a highly sensitive APD receiver with a maximum overload threshold of -7dBm. Never connect these modules back-to-back on a short fiber link (< 20km) without using an inline optical attenuator (e.g., 10dB to 15dB). Doing so will permanently destroy the APD receiver.
- Mismatched Wavelength Pairs: Purchasing two identical 1550nm-TX/1490nm-RX modules will result in a failed link. Always coordinate the A-side and B-side optics.
- Contaminated End-Faces: Dust on a Simplex LC connector over a 100km link will cause severe back-reflection and fatal dispersion penalties. Always wet/dry clean connectors before insertion.
Packaging, Shipping and Global Delivery for Networking Products
Anti-static packaging, shock-resistant protection, fast order dispatch, and reliable worldwide delivery for all LINK-PP networking products.
Anti-Static Protective Packaging
Protect networking products from electrostatic discharge and handling-related damage.
Shock-Resistant Transport Protection
Protect products against physical impacts during storage and international transportation.
Fast Order Processing and Dispatch
Accelerate order handling to ensure quick warehouse deployment.
Global Logistics and International Delivery
Ship products efficiently to customers across worldwide locations.
10G SFP+ Technical Support and Deployment Assistance
LINK-PP provides expert technical support, from product selection and compatibility verification to deployment and long-term operation.
Pre-Sales Technical Consultation
Technical consultation to help you verify EX-SFP-10GE-BX54-100 compatibility and select the appropriate product for your application.
Compatibility Verification Support
Verification support to help ensure compatibility with your equipment, applications, and deployment requirements.
Deployment & Installation Assistance
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Long-Term Technical Assurance
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
Industry Standards, Compliance and Quality Assurance
LINK-PP products are manufactured under recognized quality management systems and designed to support applicable industry standards, regulatory compliance, and long-term deployment requirements, including IEEE 802.3, RoHS, REACH, ISO 9001, and ISO 14001 where applicable. 「View Quality & Compliance Center」
ISO 9001 Quality Management
Manufactured under certified quality management processes to ensure consistent product quality and production control.
IEEE 802.3 Standards Compliance
Designed in accordance with applicable networking and Ethernet standards, including IEEE specifications where relevant.
RoHS Compliance
Manufactured using materials that support restrictions on hazardous substances for global market requirements.
REACH Compliance
Material declarations and supply chain processes support applicable REACH regulatory requirements.
Product Safety Assurance
Selected products support recognized safety and reliability requirements for networking applications.
Reliability Verification Testing
Products undergo verification and quality testing to support stable operation in enterprise, telecom, and industrial environments.
10G SFP+ Warranty and After-Sales Service
LINK-PP provides warranty coverage and after-sales support to help ensure stable operation and long-term product performance.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
Keyword:
SFP Download
Product Drawing
Juniper Compatible 10G EX-SFP-10GE-BX54-100 FAQ
Recommend
-
Nav Menu
-
About LINK-PP
-
All Products
-
Applications







































