Brocade 10G-SFPP-BXD-100K Compatible 10GBASE-BX SFP+ BiDi Optical Transceiver with DOM
P/N:
LS-BL554910-A0C
Manufacturer:
LINK-PP
Compatible Brand:
Brocade
Compatible P/N:
10G-SFPP-BXD-100K
- Compatible Brands: Brocade
- Form Factor: SFP+
- Data Rate: 10G
- Distance: ≤100km
- Type: Single Mode
- Connector: Simplex LC
- Wavelength: 1550nm-TX/1490nm-RX
- P/N: LS-BL554910-A0C
- Manufacture: LINK-PP
- Compatible Brand: Brocade
- Compatible P/N: 10G-SFPP-BXD-100K
Product Specifications
| LINK-PP Part Number | LS-BL554910-A0C | Brocade Part Number | 10G-SFPP-BXD-100K |
| Form Factor | SFP+ | Max Data Rate | 10.7 Gbps |
| Wavelength | 1550nm-TX / 1490nm-RX | Max Cable Distance | 100km |
| Connector | Simplex LC | Media | SMF |
| Optical Components | Cooled EML / APD BiDi | DOM / DDM Support | Yes |
| TX Power | -1.0 to +5.0 dBm | RX Power | -23.0 to -6.0 dBm |
| Receiver Sensitivity | ≤ -25.0 dBm | Receiver Overload | -7.0 dBm |
| Operating Case Temperature | 0°C to 70°C | Protocols | SFP+ MSA Compliant, CPRI, eCPRI |
Brocade 10G-SFPP-BXD-100K Compatible LINK-PP LS-BL554910-A0C 10G BiDi SFP+ Optical Transceiver 1550nm-TX/1490nm-RX 100km Simplex LC for DCI and Metro Networks
The LINK-PP LS-BL554910-A0C is a high-performance, Brocade 10G-SFPP-BXD-100K compatible 10G Bidirectional (BiDi) SFP+ optical transceiver engineered for ultra-long-haul Metropolitan Area Networks (MAN), Data Center Interconnects (DCI), and extended enterprise campus links. Designed to transmit and receive 10Gbps payloads over a single strand of Single-Mode Fiber (SMF) via Wavelength Division Multiplexing (WDM), this module dramatically reduces dark fiber leasing costs by doubling existing fiber capacity.
Constructed with a carrier-grade Cooled EML laser transmitter and a highly sensitive APD photodiode integrated with a trans-impedance preamplifier (TIA), this module delivers deterministic 10.7Gbps performance up to 100 kilometers. Fully compliant with SFP+ MSA and SFF-8472 standards, it provides network operations centers (NOC) and storage administrators with real-time DOM telemetry to ensure uninterrupted connectivity across critical long-haul Brocade routing and switching infrastructures.
Application Topologies and Deployment Scenarios
Understanding the strategic value of 100km BiDi optical technology is crucial for optimizing CAPEX in IP and storage networks. This transceiver is strictly optimized for environments where fiber strand availability is highly restricted and bridging massive physical distances without inline optical amplification is required.
Data Center Interconnect (DCI) and SAN Extension
In environments utilizing Brocade platforms for storage and IP networking, bridging dual data centers for Disaster Recovery (DR) requires robust long-haul optics. This 100km-rated transceiver allows architects to establish secure, high-bandwidth edge-to-edge network designs that bypass intermediate optical amplifiers, supporting IP-based SAN extension and high-speed FCoE (Fibre Channel over Ethernet) replication across metropolitan boundaries.
Metropolitan Area Networks (MAN) and Carrier Backbones
For regional ISPs and municipal networks operating Brocade MLX or VDX series routers, this module provides seamless 10G backbone connectivity across geographically dispersed Points of Presence (POPs). It establishes massive bandwidth pipelines while conserving physical fiber count on highly congested municipal fiber rings.
Fiber Resource Optimization via BiDi WDM
In legacy enterprise deployments utilizing standard dual-fiber transceivers (LR/ER/ZR), scaling network capacity requires trenching new fiber. By utilizing integrated WDM technology to multiplex TX (1550nm) and RX (1490nm) over a single Simplex LC strand, network engineers can instantly double their available fiber plant capacity for campus extensions without laying new cables.
Physical Layer Design and Optical Performance Optimization
Transmitting 10Gbps over 100 kilometers requires sophisticated optical engineering to overcome chromatic dispersion and severe signal attenuation. LINK-PP transceivers are built with superior chip-level components to ensure robust link integrity.
Cooled EML Transmitter and APD Receiver Architecture
The transmission core utilizes a Cooled EML (Electro-absorption Modulated Laser) operating at 1550nm. Compared to standard DML lasers, the Cooled EML offers significantly lower chirp and a narrower spectral width, which prevents data corruption (dispersion penalty) over ultra-long distances. The receiving end employs a highly sensitive 1490nm APD (Avalanche Photodiode), capable of accurately amplifying extremely weak optical signals after 100km of fiber attenuation.
Signal Integrity and 100km Optical Link Budget
The optical link budget is the critical metric for long-haul stability. This LS-BL554910-A0C module boasts an exceptional optical power profile engineered for substantial distance:
- Tx Output Power: -1.0 dBm to +5.0 dBm
- Rx Sensitivity: Better than -25.0 dBm
- Receiver Overload: -7.0 dBm
- Optical Link Budget: Minimum ~24 dB margin (guaranteeing 100km reach on pristine OS2 single-mode fiber)
Thermal Management and Reliability Optimization
Long-reach optics generate significant heat due to their high-power EML lasers. Designed with a premium die-cast metal housing and an integrated MCU control unit, this transceiver ensures superior thermal dissipation and EMI shielding. It operates reliably across standard commercial temperatures (0°C to 70°C), making it ideal for climate-controlled data centers and enterprise MDF/IDF closets.
Multi-Vendor Compatibility and DOM/DDM Diagnostics
Network engineers require optics that integrate universally with edge switches while providing deep visibility into the physical layer across spanning distances to prevent unexpected link degradation.
Brocade Hardware and OS Compatibility Validation
Undergoing stringent hardware and EEPROM validation, the LS-BL554910-A0C is natively recognized by Brocade operating systems (such as FastIron or Network OS) as a 10G-SFPP-BXD-100K compatible module. It bypasses proprietary vendor lock-outs, ensuring immediate plug-and-play operation in Brocade ICX series switches, VDX data center switches, and MLX routers without triggering "unsupported transceiver" warnings.
Real-Time Digital Diagnostic Monitoring (DOM/DDM)
Integrated DOM/DDM (compliant with SFF-8472) provides network administrators with real-time access to operational telemetry. Through the Brocade switch CLI (e.g., using show optic commands) or standard SNMP polling, NOC engineers can actively monitor Transceiver Temperature, TX Bias Current, Vcc Voltage, TX Optical Power, and RX Optical Power.
Remote Link Health and Preventive Maintenance
For long-haul DCI deployments, dispatching a technician to troubleshoot physical links is costly. DOM telemetry allows IT teams to monitor gradual RX power degradation caused by micro-bends in aging fiber or weather-induced splice degradation, enabling proactive maintenance scheduling before a hard link failure occurs.
Selection Guide and Deployment Considerations
Deploying 100km BiDi optics involves strict adherence to physical layer rules. Below are critical engineering guidelines to prevent hardware damage and ensure optimal transmission.
BiDi Wavelength Pairing Requirement
Bidirectional transceivers must be deployed in complementary pairs. Because this module transmits at 1550nm and receives at 1490nm (1550nm-TX / 1490nm-RX), the Brocade switch at the remote end of the fiber MUST be equipped with the exact opposite transceiver model (e.g., the 1490nm-TX / 1550nm-RX upstream counterpart, often designated as BXU) to establish a link.
Fiber Type and Distance Matching
To achieve the rated 10Gbps transmission distance without excessive dispersion penalties, your physical cabling must meet the following parameters:
- Fiber Standard: 9/125µm Single-Mode Fiber (OS2 is highly recommended over OS1 for 100km links due to lower water-peak attenuation)
- Connector Type: Simplex LC (UPC Polish)
- Splice Quality: Distance achievable is highly dependent on fiber attenuation (typically calculated at ≤ 0.25 dB/km at 1550nm) and the number of fusion splices in the path.
Common Deployment Mistakes in Long-Haul BiDi Networks
Avoid these frequent engineering errors to ensure a successful long-haul deployment:
- Receiver Burnout (Crucial): This module features a highly sensitive APD receiver with a maximum overload threshold of -7dBm. Never connect these modules back-to-back on a short fiber link (< 20km) without using an inline optical attenuator (e.g., 10dB to 15dB). Doing so will permanently destroy the APD receiver.
- Mismatched Wavelength Pairs: Purchasing two identical 1550nm-TX/1490nm-RX modules will result in a failed link. Always coordinate the A-side (Downstream) and B-side (Upstream) optics.
- Contaminated End-Faces: Dust on a Simplex LC connector over a 100km link will cause severe back-reflection and fatal dispersion penalties. Always wet/dry clean connectors before insertion.
Packaging, Shipping and Global Delivery for Networking Products
Anti-static packaging, shock-resistant protection, fast order dispatch, and reliable worldwide delivery for all LINK-PP networking products.
Anti-Static Protective Packaging
Protect networking products from electrostatic discharge and handling-related damage.
Shock-Resistant Transport Protection
Protect products against physical impacts during storage and international transportation.
Fast Order Processing and Dispatch
Accelerate order handling to ensure quick warehouse deployment.
Global Logistics and International Delivery
Ship products efficiently to customers across worldwide locations.
10G SFP+ Technical Support and Deployment Assistance
LINK-PP provides expert technical support, from product selection and compatibility verification to deployment and long-term operation.
Pre-Sales Technical Consultation
Technical consultation to help you verify 10G-SFPP-BXD-100K compatibility and select the appropriate product for your application.
Compatibility Verification Support
Verification support to help ensure compatibility with your equipment, applications, and deployment requirements.
Deployment & Installation Assistance
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Long-Term Technical Assurance
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
Industry Standards, Compliance and Quality Assurance
LINK-PP products are manufactured under recognized quality management systems and designed to support applicable industry standards, regulatory compliance, and long-term deployment requirements, including IEEE 802.3, RoHS, REACH, ISO 9001, and ISO 14001 where applicable. 「View Quality & Compliance Center」
ISO 9001 Quality Management
Manufactured under certified quality management processes to ensure consistent product quality and production control.
IEEE 802.3 Standards Compliance
Designed in accordance with applicable networking and Ethernet standards, including IEEE specifications where relevant.
RoHS Compliance
Manufactured using materials that support restrictions on hazardous substances for global market requirements.
REACH Compliance
Material declarations and supply chain processes support applicable REACH regulatory requirements.
Product Safety Assurance
Selected products support recognized safety and reliability requirements for networking applications.
Reliability Verification Testing
Products undergo verification and quality testing to support stable operation in enterprise, telecom, and industrial environments.
10G SFP+ Warranty and After-Sales Service
LINK-PP provides warranty coverage and after-sales support to help ensure stable operation and long-term product performance.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
Keyword:
SFP Download
Product Drawing
Brocade Compatible 10G 10G-SFPP-BXD-100K FAQ
Recommend
-
Nav Menu
-
About LINK-PP
-
All Products
-
Applications







































