HOT CROSS-REFERENCE SEARCHES All Products
HR911105A Cisco GLC-LH-SMD Pulse J1011F21PNL LPJG0926HENL TE 2170704-1 SFP-10G-SR
POPULAR CATEGORIES
Matched Parts (Real-time ES) Use ↑ ↓ to select, Enter to open
+
  • LS-BL554910-80I-1.webp
  • LS-BL554910-80I-2.webp
  • LS-BL554910-80I-3.webp
  • LS-BL554910-80I-4.webp
  • LS-BL554910-80I-5.webp

Brocade 10G-SFPP-BXD-80K-I Compatible Industrial 10GBASE-BX SFP+ BiDi Optical Transceiver with DOM

P/N:

LS-BL554910-80I

Manufacturer:

LINK-PP

Classification:

Compatible Brand:

Compatible P/N:

  • Compatible Brands: Brocade
  • Form Factor: SFP+
  • Data Rate: 10G
  • Distance: ≤80km
  • Type: Single Mode
  • Connector: Simplex LC
  • Model: ZR
  • Wavelength: 1550nm-TX/1490nm-RX
  • P/N: LS-BL554910-80I
  • Manufacture: LINK-PP
  • Compatible Brand: Brocade
  • Compatible P/N: 10G-SFPP-BXD-80K-I

Product Specifications

LINK-PP Part Number LS-BL554910-80I Brocade Part Number 10G-SFPP-BXD-80K-I
Form Factor SFP+ Max Data Rate 10.7 Gbps
Wavelength 1550nm-TX / 1490nm-RX Max Cable Distance 80km
Connector Simplex LC Media SMF
Optical Components Cooled EML / APD BiDi DOM / DDM Support Yes
TX Power -1.0 to +5.0 dBm RX Power -23.0 to -6.0 dBm
Receiver Sensitivity ≤ -25.0 dBm Receiver Overload -7.0 dBm
Industrial Temp Range -40°C to 85°C Protocols SFP+ MSA Compliant, CPRI, eCPRI

Brocade 10G-SFPP-BXD-80K-I Compatible LINK-PP LS-BL554910-80I 10G BiDi SFP+ Optical Transceiver 1550nm-TX/1490nm-RX 80km Simplex LC for Industrial and Metro Networks

The LINK-PP LS-BL554910-80I is a carrier-grade, Brocade 10G-SFPP-BXD-80K-I compatible 10G Bidirectional (BiDi) SFP+ optical transceiver engineered for long-haul Metropolitan Area Networks (MAN), Data Center Interconnects (DCI), and extreme-environment edge deployments. Designed to transmit and receive 10Gbps payloads over a single strand of Single-Mode Fiber (SMF) via Wavelength Division Multiplexing (WDM), this module dramatically reduces dark fiber leasing costs by doubling existing fiber capacity.

Built for harsh environments, this Industrial Temperature (-40°C to 85°C) transceiver integrates a premium Cooled EML laser and a high-sensitivity APD photodiode with a trans-impedance preamplifier (TIA). Fully compliant with CPRI, eCPRI, and SFP+ MSA standards, it delivers deterministic 10.7Gbps performance up to 80 kilometers (extending up to 100km under ideal conditions), while providing network operations centers (NOC) with real-time DOM telemetry to ensure uninterrupted connectivity across critical Brocade routing and switching infrastructures.

Application Topologies and Deployment Scenarios

Understanding the strategic value of 10G BiDi optical technology is crucial for optimizing CAPEX in IP and telecom networks. This transceiver is strictly optimized for environments where fiber strand availability is highly restricted, and physical operating conditions fluctuate severely.

Harsh Environment and Edge Connectivity

Fully compliant with industrial thermal standards, this hardened module is standardly deployed in remote outdoor enclosures, unventilated street cabinets, and cell tower base stations. It provides high-bandwidth, low-latency uplinks for 5G fronthaul networks and industrial IoT backbones, withstanding freezing winters and extreme summer heat without optical wavelength drift.

Data Center Interconnect (DCI) and SAN Extension

In environments utilizing Brocade platforms for storage and IP networking, bridging dual data centers for Disaster Recovery (DR) requires robust long-haul optics. This 80km-rated transceiver allows architects to establish secure edge-to-edge network designs that bypass intermediate optical amplifiers, supporting IP-based SAN extension and high-speed FCoE (Fibre Channel over Ethernet) replication across metropolitan boundaries.

Fiber Resource Optimization via BiDi WDM

In legacy enterprise deployments utilizing standard dual-fiber transceivers (LR/ER/ZR), scaling network capacity requires trenching new fiber. By utilizing integrated WDM technology to multiplex TX (1550nm) and RX (1490nm) over a single Simplex LC strand, network engineers can instantly double their available fiber plant capacity for campus extensions and municipal fiber rings without laying new cables.

Physical Layer Design and Optical Performance Optimization

Transmitting 10Gbps over 80 kilometers requires sophisticated optical engineering to overcome chromatic dispersion and severe signal attenuation. LINK-PP transceivers are built with superior chip-level components to ensure robust link integrity.

Cooled EML Transmitter and APD Receiver Architecture

The transmission core utilizes a Cooled EML (Electro-absorption Modulated Laser) operating at 1550nm. Compared to standard DML lasers, the Cooled EML offers significantly lower chirp and a narrower spectral width, preventing data corruption (dispersion penalty) over long distances. The receiving end employs a highly sensitive 1490nm APD (Avalanche Photodiode), capable of amplifying extremely weak optical signals after 80km of fiber attenuation.

Signal Integrity and 80km Optical Link Budget

The optical link budget is the critical metric for long-haul stability. This LS-BL554910-80I module boasts an exceptional optical power profile engineered for substantial distance:

  • Tx Output Power: -1.0 dBm to +5.0 dBm
  • Rx Sensitivity: Better than -25.0 dBm
  • Receiver Overload: -7.0 dBm
  • Optical Link Budget: ~24 dB margin (guaranteeing 80km reach, extending up to 100km on pristine OS2 single-mode fiber)

Hardened Industrial Thermal Management

Unlike commercial optics (0°C to 70°C), this industrial-rated transceiver is equipped with a specialized MCU control unit and die-cast thermal dissipation housing to operate flawlessly from -40°C to +85°C (-40°F to 185°F). It prevents laser wavelength drift and completely eliminates component failure risks in uncontrolled edge environments.

Multi-Vendor Compatibility and DOM/DDM Diagnostics

Network engineers require optics that integrate universally with edge switches while providing deep visibility into the physical layer across spanning distances to prevent unexpected link degradation.

Brocade Hardware and OS Compatibility Validation

Undergoing stringent hardware and EEPROM validation, the LS-BL554910-80I is natively recognized by Brocade operating systems (such as FastIron, NetIron, or Network OS) as a 10G-SFPP-BXD-80K-I compatible module. It bypasses proprietary vendor lock-outs, ensuring immediate plug-and-play operation in Brocade ICX series switches, VDX data center switches, and MLX routers without triggering "unsupported transceiver" warnings or syslogs.

Real-Time Digital Diagnostic Monitoring (DOM/DDM)

Integrated DOM/DDM (compliant with SFF-8472) provides network administrators with real-time access to operational telemetry. Through the Brocade switch CLI (e.g., using show optic commands) or standard SNMP polling, NOC engineers can actively monitor Transceiver Temperature, TX Bias Current, Vcc Voltage, TX Optical Power, and RX Optical Power.

Remote Link Health and Preventive Maintenance

For outdoor and long-haul deployments, dispatching a technician is costly. DOM telemetry allows IT teams to monitor gradual RX power degradation caused by micro-bends in aging fiber or weather-induced splice degradation, enabling proactive maintenance scheduling before a hard link failure occurs.

Selection Guide and Deployment Considerations

Deploying 80km BiDi optics involves strict adherence to physical layer rules. Below are critical engineering guidelines to prevent hardware damage and ensure optimal transmission.

BiDi Wavelength Pairing Requirement

Bidirectional transceivers must be deployed in complementary pairs. Because this module transmits at 1550nm and receives at 1490nm (1550nm-TX / 1490nm-RX), the switch at the remote end of the fiber MUST be equipped with the exact opposite transceiver model (e.g., the 1490nm-TX / 1550nm-RX upstream counterpart, often designated as BXU) to establish a link.

Fiber Type and Distance Matching

To achieve the rated 10Gbps transmission distance, your physical cabling must meet the following parameters:

  • Fiber Standard: 9/125µm Single-Mode Fiber (OS1 or OS2; OS2 highly recommended for >50km links)
  • Connector Type: Simplex LC (UPC Polish)
  • Max Cable Distance: 80km standard (Up to 100km depending on splice quality and fiber attenuation < 0.25 dB/km)

Common Deployment Mistakes in Long-Haul BiDi Networks

Avoid these frequent engineering errors to ensure a successful long-haul deployment:

  • Receiver Burnout (Crucial): This module features a highly sensitive APD receiver with a maximum overload threshold of -7dBm. Never connect these modules back-to-back on a short fiber (< 20km) without using an inline optical attenuator (e.g., 10dB to 15dB). Doing so will permanently destroy the APD receiver.
  • Mismatched Wavelength Pairs: Purchasing two identical 1550nm-TX/1490nm-RX modules will result in a failed link. Always order and deploy the matching A-side (Downstream) and B-side (Upstream) optics.
  • Contaminated End-Faces: Dust on a Simplex LC connector over an 80km link will cause severe back-reflection and fatal dispersion penalties. Always wet/dry clean connectors before insertion.

Packaging, Shipping and Global Delivery for Networking Products

Anti-static packaging, shock-resistant protection, fast order dispatch, and reliable worldwide delivery for all LINK-PP networking products.

Anti-Static Protective Packaging

Anti-Static Protective Packaging

Protect networking products from electrostatic discharge and handling-related damage.

Shock-Resistant Transport Protection

Shock-Resistant Transport Protection

Protect products against physical impacts during storage and international transportation.

Fast Order Processing and Dispatch

Fast Order Processing and Dispatch

Accelerate order handling to ensure quick warehouse deployment.

Global Logistics and International Delivery

Global Logistics and International Delivery

Ship products efficiently to customers across worldwide locations.

10G SFP+ Technical Support and Deployment Assistance

LINK-PP provides expert technical support, from product selection and compatibility verification to deployment and long-term operation.

Pre-Sales Technical Consultation

Pre-Sales Technical Consultation

Technical consultation to help you verify 10G-SFPP-BXD-80K-I compatibility and select the appropriate product for your application.

Compatibility Verification Support

Compatibility Verification Support

Verification support to help ensure compatibility with your equipment, applications, and deployment requirements.

Deployment & Installation Assistance

Deployment & Installation Assistance

Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.

Long-Term Technical Assurance

Long-Term Technical Assurance

Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.

Industry Standards, Compliance and Quality Assurance

LINK-PP products are manufactured under recognized quality management systems and designed to support applicable industry standards, regulatory compliance, and long-term deployment requirements, including IEEE 802.3, RoHS, REACH, ISO 9001, and ISO 14001 where applicable. 「View Quality & Compliance Center」

ISO 9001 Quality Management System Certification

ISO 9001 Quality Management

Manufactured under certified quality management processes to ensure consistent product quality and production control.

IEEE 802.3 Ethernet Standard Compliance

IEEE 802.3 Standards Compliance

Designed in accordance with applicable networking and Ethernet standards, including IEEE specifications where relevant.

RoHS Compliance

RoHS Compliance

Manufactured using materials that support restrictions on hazardous substances for global market requirements.

REACH Compliance

REACH Compliance

Material declarations and supply chain processes support applicable REACH regulatory requirements.

Product Safety Assurance

Product Safety Assurance

Selected products support recognized safety and reliability requirements for networking applications.

Reliability Verification Testing

Reliability Verification Testing

Products undergo verification and quality testing to support stable operation in enterprise, telecom, and industrial environments.

10G SFP+ Warranty and After-Sales Service

LINK-PP provides warranty coverage and after-sales support to help ensure stable operation and long-term product performance.

15 days

15-day no-reason return and refund

Free maintenance or replacement

Free replacement for dead-on-arrival (DOA) or defective items within the initial period

Free maintenance

Free repair services for manufacturing defects throughout the warranty period

Limitations

Warranty exclusions and conditions apply

Keyword: