Extreme 10GB-BX80-D-I Compatible Industrial 10GBASE-BX80 SFP+ BiDi Optical Transceiver with DOM
P/N:
LS-BL554910-80I
Manufacturer:
LINK-PP
Compatible Brand:
Extreme
Compatible P/N:
10GB-BX80-D-I
- Compatible Brands: Extreme
- Form Factor: SFP+
- Data Rate: 10G
- Distance: ≤80km
- Type: Single Mode
- Connector: Simplex LC
- Model: ZR
- Wavelength: 1550nm-TX/1490nm-RX
- P/N: LS-BL554910-80I
- Manufacture: LINK-PP
- Compatible Brand: Extreme
- Compatible P/N: 10GB-BX80-D-I
Product Specifications
| LINK-PP Part Number | LS-BL554910-80I | Extreme Part Number | 10GB-BX80-D-I |
| Form Factor | SFP+ | Max Data Rate | 10.7 Gbps |
| Wavelength | 1550nm-TX / 1490nm-RX | Max Cable Distance | 80km |
| Connector | Simplex LC | Media | SMF (Single-Mode Fiber) |
| Optical Components | Cooled EML / APD BiDi | DOM / DDM Support | Yes |
| TX Power | -1.0 to +5.0 dBm | RX Power | -23.0 to -6.0 dBm |
| Receiver Sensitivity | ≤ -25.0 dBm | Receiver Overload | -7.0 dBm |
| Industrial Temp Range | -40°C to 85°C | Protocols | SFP+ MSA Compliant, CPRI, eCPRI |
Extreme Networks 10GB-BX80-D-I Compatible LINK-PP LS-BL554910-80I 10G BiDi SFP+ Optical Transceiver 1550nm-TX/1490nm-RX 80km Simplex LC for Industrial Telecom Networks
The LINK-PP LS-BL554910-80I is a carrier-grade, Extreme Networks 10GB-BX80-D-I compatible 10G Bidirectional (BiDi) SFP+ optical transceiver engineered for long-haul Metropolitan Area Networks (MAN), ISP backbones, and extreme-environment edge deployments. Designed to transmit and receive 10Gbps payloads over a single strand of Single-Mode Fiber (SMF) via Wavelength Division Multiplexing (WDM), this module dramatically reduces dark fiber leasing costs by doubling existing fiber capacity.
Built for harsh environments, this Industrial Temperature (-40°C to 85°C) transceiver integrates a premium Cooled EML laser and a high-sensitivity APD photodiode with a trans-impedance preamplifier (TIA). Fully compliant with CPRI, eCPRI, and SFP+ MSA standards, it delivers deterministic 10.7Gbps performance up to 80 kilometers (extending up to 100km under ideal conditions), while providing network operations centers (NOC) with real-time DOM telemetry to ensure uninterrupted connectivity across critical Extreme Networks routing and switching infrastructures.
Application Topologies and Deployment Scenarios
Understanding the strategic value of 10G BiDi optical technology is crucial for optimizing CAPEX in IP and telecom networks. This transceiver is strictly optimized for environments where fiber strand availability is highly restricted, and physical operating conditions fluctuate severely.
Harsh Environment and 5G Fronthaul Connectivity
Fully compliant with industrial thermal standards, this hardened module is standardly deployed in remote outdoor enclosures, unventilated street cabinets, and cell tower base stations. It provides high-bandwidth, low-latency uplinks for 5G fronthaul networks (connecting Baseband Units to Remote Radio Heads) and industrial IoT backbones, withstanding freezing winters and extreme summer heat without optical wavelength drift.
Metropolitan Area Networks (MAN) and Carrier Backbones
For regional ISPs and municipal networks operating Extreme routing platforms, bridging distances between metropolitan POPs (Points of Presence) requires high optical budgets. This 80km-rated transceiver allows network architects to bypass intermediate optical amplifiers or repeaters in many long-haul edge-to-core designs, dramatically simplifying the transmission topology.
Fiber Resource Optimization via BiDi WDM
In legacy enterprise deployments utilizing standard dual-fiber transceivers (LR/ER/ZR), scaling network capacity requires trenching new fiber. By utilizing integrated WDM technology to multiplex TX (1550nm) and RX (1490nm) over a single Simplex LC strand, network engineers can instantly double their available fiber plant capacity for campus extensions and municipal fiber rings without laying new cables.
Physical Layer Design and Optical Performance Optimization
Transmitting 10Gbps over 80 kilometers requires sophisticated optical engineering to overcome chromatic dispersion and severe signal attenuation. LINK-PP transceivers are built with superior chip-level components to ensure robust link integrity.
Cooled EML Transmitter and APD Receiver Architecture
The transmission core utilizes a Cooled EML (Electro-absorption Modulated Laser) operating at 1550nm. Compared to standard DML lasers, the Cooled EML offers significantly lower chirp and a narrower spectral width, preventing data corruption (dispersion penalty) over long distances. The receiving end employs a highly sensitive 1490nm APD (Avalanche Photodiode), capable of amplifying extremely weak optical signals after 80km of fiber attenuation.
Signal Integrity and 80km Optical Link Budget
The optical link budget is the critical metric for long-haul stability. This LS-BL554910-80I module boasts an exceptional optical power profile engineered for substantial distance:
- Tx Output Power: -1.0 dBm to +5.0 dBm
- Rx Sensitivity: Better than -25.0 dBm
- Receiver Overload: -7.0 dBm
- Optical Link Budget: ~24 dB margin (guaranteeing 80km reach, extending up to 100km on pristine OS2 single-mode fiber)
Hardened Industrial Thermal Management
Unlike commercial optics (0°C to 70°C), this industrial-rated transceiver is equipped with a specialized MCU control unit and die-cast thermal dissipation housing to operate flawlessly from -40°C to +85°C (-40°F to 185°F). It prevents laser wavelength drift and completely eliminates component failure risks in uncontrolled edge environments.
Multi-Vendor Compatibility and DOM/DDM Diagnostics
Network engineers require optics that integrate universally with edge switches while providing deep visibility into the physical layer across spanning distances to prevent unexpected link degradation.
Extreme Hardware and EXOS/VOSS Compatibility Validation
Undergoing stringent hardware and EEPROM validation, the LS-BL554910-80I is natively recognized by Extreme Networks operating systems (such as EXOS and VOSS) as a 10GB-BX80-D-I compatible module. It bypasses proprietary vendor lock-outs, ensuring immediate plug-and-play operation in ExtremeSwitching platforms (e.g., X-Series, VSP Series, and SLX routers) without triggering "unsupported transceiver" warnings or syslogs.
Real-Time Digital Diagnostic Monitoring (DOM/DDM)
Integrated DOM/DDM (compliant with SFF-8472) provides network administrators with real-time access to operational telemetry. Through the Extreme switch CLI (using commands like show ports transceiver information detail) or standard SNMP polling, NOC engineers can actively monitor Transceiver Temperature, TX Bias Current, Vcc Voltage, TX Optical Power, and RX Optical Power.
Remote Link Health and Preventive Maintenance
For outdoor and long-haul deployments, dispatching a technician is costly. DOM telemetry allows IT teams to monitor gradual RX power degradation caused by micro-bends in aging fiber or weather-induced splice degradation, enabling proactive maintenance scheduling before a hard link failure occurs.
Selection Guide and Deployment Considerations
Deploying 80km BiDi optics involves strict adherence to physical layer rules. Below are critical engineering guidelines to prevent hardware damage and ensure optimal transmission.
BiDi Wavelength Pairing Requirement
Bidirectional transceivers must be deployed in complementary pairs. Because this downstream ("D") module transmits at 1550nm and receives at 1490nm (1550nm-TX / 1490nm-RX), the switch at the remote end of the fiber MUST be equipped with the exact opposite upstream transceiver model (e.g., 10GB-BX80-U-I, which is 1490nm-TX / 1550nm-RX) to establish a link.
Fiber Type and Distance Matching
To achieve the rated 10Gbps transmission distance, your physical cabling must meet the following parameters:
- Fiber Standard: 9/125µm Single-Mode Fiber (OS1 or OS2; OS2 highly recommended for >50km links)
- Connector Type: Simplex LC (UPC Polish)
- Max Cable Distance: 80km standard (Up to 100km depending on splice quality and fiber attenuation < 0.25 dB/km)
Common Deployment Mistakes in Long-Haul BiDi Networks
Avoid these frequent engineering errors to ensure a successful long-haul deployment:
- Receiver Burnout (Crucial): This module features a highly sensitive APD receiver with a maximum overload threshold of -7dBm. Never connect these modules back-to-back on a short fiber (< 20km) without using an inline optical attenuator (e.g., 10dB to 15dB). Doing so will permanently destroy the APD receiver.
- Mismatched Wavelength Pairs: Purchasing two identical 1550nm-TX/1490nm-RX modules will result in a failed link. Always order and deploy the matching A-side (Downstream) and B-side (Upstream) optics.
- Contaminated End-Faces: Dust on a Simplex LC connector over an 80km link will cause severe back-reflection and fatal dispersion penalties. Always wet/dry clean connectors before insertion.
Packaging, Shipping and Global Delivery for Networking Products
Anti-static packaging, shock-resistant protection, fast order dispatch, and reliable worldwide delivery for all LINK-PP networking products.
Anti-Static Protective Packaging
Protect networking products from electrostatic discharge and handling-related damage.
Shock-Resistant Transport Protection
Protect products against physical impacts during storage and international transportation.
Fast Order Processing and Dispatch
Accelerate order handling to ensure quick warehouse deployment.
Global Logistics and International Delivery
Ship products efficiently to customers across worldwide locations.
10G SFP+ Technical Support and Deployment Assistance
LINK-PP provides expert technical support, from product selection and compatibility verification to deployment and long-term operation.
Pre-Sales Technical Consultation
Technical consultation to help you verify 10GB-BX80-D-I compatibility and select the appropriate product for your application.
Compatibility Verification Support
Verification support to help ensure compatibility with your equipment, applications, and deployment requirements.
Deployment & Installation Assistance
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Long-Term Technical Assurance
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
Industry Standards, Compliance and Quality Assurance
LINK-PP products are manufactured under recognized quality management systems and designed to support applicable industry standards, regulatory compliance, and long-term deployment requirements, including IEEE 802.3, RoHS, REACH, ISO 9001, and ISO 14001 where applicable. 「View Quality & Compliance Center」
ISO 9001 Quality Management
Manufactured under certified quality management processes to ensure consistent product quality and production control.
IEEE 802.3 Standards Compliance
Designed in accordance with applicable networking and Ethernet standards, including IEEE specifications where relevant.
RoHS Compliance
Manufactured using materials that support restrictions on hazardous substances for global market requirements.
REACH Compliance
Material declarations and supply chain processes support applicable REACH regulatory requirements.
Product Safety Assurance
Selected products support recognized safety and reliability requirements for networking applications.
Reliability Verification Testing
Products undergo verification and quality testing to support stable operation in enterprise, telecom, and industrial environments.
10G SFP+ Warranty and After-Sales Service
LINK-PP provides warranty coverage and after-sales support to help ensure stable operation and long-term product performance.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply