HOT CROSS-REFERENCE SEARCHES All Products
HR911105A Cisco GLC-LH-SMD Pulse J1011F21PNL LPJG0926HENL TE 2170704-1 SFP-10G-SR
POPULAR CATEGORIES
Matched Parts (Real-time ES) Use ↑ ↓ to select, Enter to open
+
  • LS-CW4910-20C-1.webp
  • LS-CW4910-20C-2.webp
  • LS-CW4910-20C-3.webp
  • LS-CW4910-20C-4.webp
  • LS-CW4910-20C-5.webp

Cisco CWDM-SFP10G-1490-20 Compatible LS-CW4910-20C SFP+ 10G CWDM 1490nm 20km DOM Duplex LC/UPC SMF Optical Transceiver Module

P/N:

LS-CW4910-20C

Manufacturer:

LINK-PP

Classification:

Compatible Brand:

Cisco

Compatible P/N:

CWDM-SFP10G-1490-20

  • Compatible Brands: Cisco
  • Form Factor: SFP+
  • Data Rate: 10G
  • Distance: ≤20km
  • Type: Single Mode
  • Connector: Duplex LC
  • Wavelength: 1350nm-1610nm
  • P/N: LS-CW4910-20C
  • Manufacture: LINK-PP
  • Compatible Brand: Cisco
  • Compatible P/N: CWDM-SFP10G-1490-20

Product Specifications

LINK-PP Part Number LS-CW4910-20C Cisco Part Number CWDM-SFP10G-1490-20
Form Factor SFP+ Max Data Rate 10Gbps
Wavelength 1490nm Max Cable Distance 20km
Connector Duplex LC Media SMF
Optical Components DFB CWDM DOM Support Yes
TX Power -1 to +5dBm RX Power -23 to -6dBm
Receiver Sensitivity -16dBm Receiver Overload 0dBm
Commercial temperature Range 0 to 70°C Protocols SFP+ MSA Compliant, CPRI, eCPRI, ITU-T G.652

Cisco CWDM-SFP10G-1490-20 Compatible LINK-PP LS-CW4910-20C 10G 1490nm CWDM SFP+ Transceiver Technical Overview

The LINK-PP LS-CW4910-20C (engineered as a 100% optical and EEPROM drop-in replacement for Cisco CWDM-SFP10G-1490-20) is a high-performance 10G CWDM SFP+ optical transceiver module delivering 10 Gbps data transmission over 20 km on standard Single-Mode Fiber (SMF, G.652) at the 1490nm CWDM wavelength grid via Duplex LC/UPC connectors. Powered by an uncooled 1490nm CWDM DFB laser transmitter (-1 to +5 dBm TX power), a PIN photodiode receiver (-16 dBm sensitivity), and an SFF-8472 compliant Digital Diagnostics Monitoring (DOM) interface, it provides a 15 dB optical budget for passive CWDM MUX/DEMUX networks, enterprise core switches, and 5G wireless CPRI/eCPRI front-haul links.

  • 1490nm CWDM Coarse Wavelength Division Multiplexing: Transmits on the ITU-T G.694.2 1490nm CWDM wavelength grid, allowing multiple 10G optical channels to be multiplexed onto a single duplex LC SMF fiber pair using passive CWDM filters.
  • 15 dB Optical Power Budget: Combines a 1490nm CWDM DFB laser transmitter (-1 dBm min TX power) and a PIN receiver (-16 dBm sensitivity, 0 dBm overload), delivering 20 km SMF reach with margin for CWDM MUX/DEMUX insertion loss.
  • Real-Time Digital Diagnostic Monitoring (DOM): SFF-8472 compliant 2-wire I2C diagnostic interface tracking optical TX power, optical RX power, laser bias current, supply voltage, and internal transceiver temperature.
  • Cisco Switch EEPROM Interoperability: Pre-programmed with Cisco vendor-specific EEPROM data maps, guaranteeing seamless plug-and-play operation in Cisco Catalyst, Nexus, and ASR series switches without triggering vendor lock errors.

LINK-PP LS-CW4910-20C 10G CWDM 1490nm SFP+ Optical Transceiver Overview

LINK-PP LS-CW4910-20C is a hot-pluggable 10Gbps CWDM SFP+ optical transceiver module engineered for Coarse Wavelength Division Multiplexing (CWDM) single-mode fiber interconnects up to 20 kilometers. Featuring a 1490nm DFB laser, a PIN photodiode receiver, Duplex LC optical interfaces, and full Digital Diagnostic Monitoring (DOM) capabilities, this module maintains clean optical eye diagrams and ultra-low bit error rates (BER < 10^-12). Pre-coded for complete interoperability with Cisco networking hardware, it serves as a fully qualified secondary-source replacement for Cisco CWDM-SFP10G-1490-20 OEM transceivers.

Key Benefits of LINK-PP LS-CW4910-20C / Cisco CWDM-SFP10G-1490-20 Compatible Transceiver

  • ITU-T G.694.2 1490nm CWDM Channel Integration: Enables multi-channel 10G optical multiplexing over existing single-mode fiber cables, multiplying fiber capacity without laying new optical cable plants.
  • Seamless Cisco Hardware Interoperability: Pre-loaded with Cisco-compatible EEPROM coding, bypassing non-Cisco optical warnings in Cisco IOS, IOS-XE, and NX-OS operating systems for true plug-and-play deployment.
  • 20km Single-Mode Fiber Transmission via 1490nm CWDM DFB Optics: Utilizes a precision 1490nm CWDM DFB laser and PIN receiver engine engineered to overcome optical filter insertion loss and G.652 single-mode fiber attenuation.
  • 15 dB Optical Power Budget (-1 dBm TX Min to -16 dBm RX Sensitivity): High receiver sensitivity (-16 dBm) and high output power (-1 to +5 dBm) provide ample optical margin for passive CWDM MUX/DEMUX pass-through losses (~1.5–2.5 dB per end).
  • Real-Time Diagnostic Telemetry via SFF-8472 DOM: Integrates an internal MCU control unit providing real-time telemetry tracking of TX power, RX power, bias current, temperature, and VCC voltage directly via switch CLI software.
  • Hot-Pluggable SFP+ MSA Compliant Form Factor: Easily inserted or removed from active SFP+ switch ports without interrupting host equipment power or adjacent CWDM optical channels.

10G CWDM Wavelength Multiplexing & 1490nm DFB Architecture

The LINK-PP LS-CW4910-20C is built on an advanced 10G CWDM electro-optic engine adhering to SFF-8431 electrical, SFF-8432 mechanical, and ITU-T G.694.2 CWDM grid specifications. Designed for 10.3125 Gbps serial optical communications, it maintains high optical signal-to-noise ratios (SNR).

1490nm CWDM DFB Transmitter & PIN Receiver Engine

The optical transmitter incorporates an uncooled 1490nm CWDM Distributed Feedback (DFB) laser diode operating with an average TX power between -1 dBm and +5 dBm. On the receive side, a high-sensitivity PIN photodiode combined with a Trans-Impedance Preamplifier (TIA) provides an optical sensitivity of -16 dBm and an overload threshold of 0 dBm. This establishes a robust 15 dB optical power budget, allowing 20 km SMF transmission with margin for passive CWDM multiplexer/demultiplexer filter insertion loss.

SFF-8472 Digital Diagnostic Monitoring (DOM) Diagnostics

Utilizing an I2C 2-wire serial interface mapped to memory address A2h per SFF-8472, the module provides real-time DOM telemetry. Network administrators can query live transceiver operating parameters—including optical input/output power in dBm or mW—allowing proactive CWDM link budget tracking and rapid optical fault isolation.

Cisco Switch Interoperability & EEPROM Coding

Deploying third-party CWDM optics in Cisco switches requires precise vendor firmware matching. LINK-PP eliminates this challenge by programming each LS-CW4910-20C module with Cisco-specific EEPROM memory maps.

Plug-and-Play Compliance in Cisco IOS & NX-OS

Each transceiver is flashed with accurate Cisco vendor data, part numbers, and serial numbers. Upon insertion into Cisco Catalyst (3850, 9300, 9500), Nexus (3000, 9000), or ASR series equipment connected to passive CWDM MUX/DEMUX panels, the host operating system recognizes the module instantly as an OEM CWDM-SFP10G-1490-20 optics module without requiring manual CLI overrides or throwing `UNSUPPORTED_TRANSCEIVER` syslog warnings.

Target Applications: Passive CWDM Networks, Enterprise Core, and 5G

Combining 10Gbps speed, 1490nm CWDM optics, SFF-8472 DOM telemetry, and Cisco compatibility, the LINK-PP LS-CW4910-20C supports critical optical infrastructure:

  • Passive CWDM Fiber Channel Multiplexing Networks: Ideal for expanding fiber transmission capacity over existing single-mode fiber pairs using passive CWDM MUX/DEMUX filters.
  • Enterprise Core Switch 10GbE CWDM Uplinks: Deployed in multi-building campus backbones and enterprise core switches requiring specific CWDM wavelength routing.
  • 5G Wireless CPRI / eCPRI Optical Front-Haul Networks: Suitable for wireless baseband unit (BBU/DU) to remote radio head (RRH/RU) CWDM optical front-haul links.

How to Select and Verify LS-CW4910-20C vs. Cisco CWDM-SFP10G-1490-20

Network architects and CWDM optics managers evaluating the LINK-PP LS-CW4910-20C should verify the following core parameters:

  • CWDM Wavelength Channel Matching: Confirm that your passive CWDM MUX/DEMUX filter panel features a dedicated 1490nm channel port, as wavelength mismatch will block optical signal transmission.
  • Optical Cable Matching (SMF 9/125µm vs MMF): Confirm that your installed optical fiber infrastructure uses 9/125µm Single-Mode Fiber (SMF, G.652) with Duplex LC/UPC connectors.
  • CWDM MUX/DEMUX Pass-Through Loss Calculation: Calculate total link loss including fiber attenuation (~0.35 dB/km) and passive CWDM MUX/DEMUX insertion loss (~1.5–2.5 dB per end) to ensure total loss remains within the 15 dB power budget.
  • DOM Telemetry & Cisco CLI Verification: Verify transceiver status via Cisco IOS CLI commands such as `show interfaces transceiver` and `show interfaces transceiver detail` to inspect live optical launch and receive power levels.

Frequently Asked Questions

Is LINK-PP LS-CW4910-20C compatible with Cisco CWDM-SFP10G-1490-20?

Yes. LINK-PP LS-CW4910-20C is a 100% optical, electrical, and EEPROM drop-in replacement for Cisco CWDM-SFP10G-1490-20, pre-programmed for plug-and-play compatibility with Cisco Catalyst, Nexus, and ASR switches.

What is CWDM and why use the 1490nm wavelength?

Coarse Wavelength Division Multiplexing (CWDM) combines multiple optical signals on different wavelengths onto a single fiber pair. The 1490nm wavelength is an ITU-T G.694.2 standard CWDM channel used in multi-wavelength 10G networks to increase bandwidth without laying new cables.

What cable type and maximum distance are supported by LS-CW4910-20C?

The module operates at 1490nm over standard 9/125µm Single-Mode Fiber (SMF, G.652) using Duplex LC connectors, supporting maximum link distances up to 20 kilometers (12.4 miles).

Does LS-CW4910-20C support Digital Optical Monitoring (DOM)?

Yes. The module features full DOM / DDM diagnostic support per SFF-8472, providing real-time telemetry monitoring for TX power, RX power, bias current, supply voltage, and internal temperature via switch software.

What optical components are used in LS-CW4910-20C?

LINK-PP LS-CW4910-20C incorporates an uncooled 1490nm CWDM DFB (Distributed Feedback) laser transmitter (-1 to +5 dBm) and a PIN photodiode receiver with integrated TIA preamplifier achieving -16 dBm sensitivity.

Will using LINK-PP LS-CW4910-20C void my Cisco switch warranty?

No. Networking hardware vendors cannot void equipment warranties simply for using third-party MSA-compliant optical transceivers (per Magnuson-Moss Warranty Act). LINK-PP modules are fully tested to ensure safe electrical and thermal operation in Cisco equipment.

Packaging, Shipping and Global Delivery for Networking Products

Anti-static packaging, shock-resistant protection, fast order dispatch, and reliable worldwide delivery for all LINK-PP networking products.

Anti-Static Protective Packaging

Anti-Static Protective Packaging

Protect networking products from electrostatic discharge and handling-related damage.

Shock-Resistant Transport Protection

Shock-Resistant Transport Protection

Protect products against physical impacts during storage and international transportation.

Fast Order Processing and Dispatch

Fast Order Processing and Dispatch

Accelerate order handling to ensure quick warehouse deployment.

Global Logistics and International Delivery

Global Logistics and International Delivery

Ship products efficiently to customers across worldwide locations.

10G SFP+ Technical Support and Deployment Assistance

LINK-PP provides expert technical support, from product selection and compatibility verification to deployment and long-term operation.

Pre-Sales Technical Consultation

Pre-Sales Technical Consultation

Technical consultation to help you verify CWDM-SFP10G-1490-20 compatibility and select the appropriate product for your application.

Compatibility Verification Support

Compatibility Verification Support

Verification support to help ensure compatibility with your equipment, applications, and deployment requirements.

Deployment & Installation Assistance

Deployment & Installation Assistance

Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.

Long-Term Technical Assurance

Long-Term Technical Assurance

Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.

Industry Standards, Compliance and Quality Assurance

LINK-PP products are manufactured under recognized quality management systems and designed to support applicable industry standards, regulatory compliance, and long-term deployment requirements, including IEEE 802.3, RoHS, REACH, ISO 9001, and ISO 14001 where applicable. 「View Quality & Compliance Center」

ISO 9001 Quality Management System Certification

ISO 9001 Quality Management

Manufactured under certified quality management processes to ensure consistent product quality and production control.

IEEE 802.3 Ethernet Standard Compliance

IEEE 802.3 Standards Compliance

Designed in accordance with applicable networking and Ethernet standards, including IEEE specifications where relevant.

RoHS Compliance

RoHS Compliance

Manufactured using materials that support restrictions on hazardous substances for global market requirements.

REACH Compliance

REACH Compliance

Material declarations and supply chain processes support applicable REACH regulatory requirements.

Product Safety Assurance

Product Safety Assurance

Selected products support recognized safety and reliability requirements for networking applications.

Reliability Verification Testing

Reliability Verification Testing

Products undergo verification and quality testing to support stable operation in enterprise, telecom, and industrial environments.

10G SFP+ Warranty and After-Sales Service

LINK-PP provides warranty coverage and after-sales support to help ensure stable operation and long-term product performance.

15 days

15-day no-reason return and refund

Free maintenance or replacement

Free replacement for dead-on-arrival (DOA) or defective items within the initial period

Free maintenance

Free repair services for manufacturing defects throughout the warranty period

Limitations

Warranty exclusions and conditions apply

Keyword:

SFP Download