Product Categories
Timor-Leste Cisco OSFP800-2LR4-A2 Compatible LINK-PP 800G 2LR4 OSFP CWDM IHS/Closed Finned Top 1310nm 10km Dual Duplex LC SMF Transceiver Module
- Compatible Brands: Cisco
- Form Factor: OSFP
- Data Rate: 800G
- Distance: ≤10km
- Type: Single Mode
- Connector: Duplex LC
- Model: 2LR4
- Wavelength: 1270nm-1330nm
- P/N: LO-CW800-2LR4C
- Manufacture: LINK-PP
- Compatible Brand: Cisco
- Compatible P/N: OSFP800-2LR4-A2
Category:
Product Description
Product Specifications
| Cisco Part Number | OSFP800-2LR4-A2 | Vendor Name | LINK-PP |
| Form Factor | Twin-port OSFP IHS/Closed Finned Top | Max Data Rate | 850Gbps (8x 106.25Gbps) |
| Max Cable Distance | 10km | Wavelength | 1271nm, 1291nm, 1311nm and 1331nm |
| Connector | Dual Duplex LC | Media | SMF |
| Transmitter Type | EML | Receiver Type | Siphotonics PIN PD |
| DDM/DOM | Supported | Operating Temperature Range | 0°C to +70°C |
| Modulation (Electrical) | 8x100G-PAM4 | Modulation (Optical) | Dual 4x 100G-PAM4 |
| Protocols | OSFP MSA HW Rev 4.1, CMIS Rev 5.0, MSA- 2x400G-LR4-10, IEEE P802.3ck D3.0 | Inbuilt FEC | No |
Cisco OSFP800-2LR4-A2 Compatible LINK-PP LO-CW800-2LR4C 800GBASE-2LR4 QSFP-DD Optical Transceiver 10km Dual Duplex LC CWDM4 Closed Finned Top (IHS) for Cisco Cloud Networks
The LINK-PP LO-CW800-2LR4C is a high-performance, Cisco OSFP800-2LR4-A2 compatible 800GBASE-2LR4 / 2x400G-LR4-10 Twin-Port OSFP (Octal Small Form-factor Pluggable) optical transceiver engineered for Metropolitan Area Networks (MAN), Data Center Interconnects (DCI), and expansive campus backbones spanning physical distances up to 10 kilometers. Designed with an Integrated Heat Sink (IHS / Closed Finned Top), this module features a specialized shrouded fin structure engineered to optimize static pressure airflow and direct heat removal in high-density Cisco 800G switch chassis.
Architected with an 8x 100G-PAM4 electrical interface and two independent CWDM4 optical engines multiplexing across 1271nm, 1291nm, 1311nm, and 1331nm grid wavelengths, the module achieves an aggregate data rate of 850Gbps (8x 106.25Gbps). Fully compliant with IEEE P802.3ck D3.0, 100G Lambda MSA / 2x400G-LR4-10, OSFP MSA HW Rev 4.1, and CMIS 5.0, it integrates high-power 1310nm-band EML lasers paired with a high-sensitivity SiFotonics Photodiode (PD) array to guarantee a zero-loss physical layer across extended 10km single-mode links. Featuring a Dual Duplex LC interface, it allows network architects to deploy native 800G bandwidth or two independent 400G-LR4 links using standard duplex LC fiber patch cords directly from Cisco 8000 and Nexus 9000 Series platforms.
Application Topologies and Deployment Scenarios
Extending 800G Ethernet to 10 kilometers introduces severe insertion loss and dispersion challenges. The Dual Duplex LC architecture of this 2LR4 transceiver provides an elegant solution for medium-to-long reach optical routing in high-density Cisco networks.
Native 2x 400GBASE-LR4 Breakout via Standard Duplex LC Cabling
The primary architectural advantage of the Dual Duplex LC design is direct LC cable integration. Instead of deploying specialized MPO breakout cassettes or Y-cables, network engineers can plug two standard duplex LC/UPC fiber patch cords directly into the front of a single 800G transceiver. This allows an 800G OSFP port on a Cisco core router (such as the Cisco 8000 Series powered by Silicon One) to operate seamlessly as two physically separate 400G-LR4 links (400G-LR4-10), connecting directly to two legacy 400G switches up to 10km away.
Campus and Metropolitan Area Networks (MAN/DCI)
When connecting geographically separated data center halls, central offices, or enterprise buildings across a city, 500m (DR8) or 2km (XDR8) optics fall short. The 800GBASE-2LR4 provides the necessary optical power margin to traverse up to 10km of OS2 fiber, enabling lossless, microsecond-latency RDMA (RoCEv2) traffic to flow between distant AI compute nodes and disaster recovery (DR) storage sites across Cisco Silicon One fabrics.
Eliminating MPO Cable Costs in Long-Reach Cisco Fabrics
MPO cabling over long 10km runs is prohibitively expensive and prone to high insertion loss at every splice point. By multiplexing 4 wavelengths internally onto a single pair of LC fibers (CWDM4 technology), this module allows operators to run high-density 800G traffic over traditional 2-fiber LC duplex plant infrastructure, dramatically reducing optical fiber leasing and cabling costs.
Physical Layer Design and Optical Performance Optimization
Transmitting 100Gbps per lane over 10 kilometers of single-mode fiber requires highly sophisticated optical WDM engineering to overcome chromatic dispersion. LINK-PP transceivers integrate advanced optical engines to guarantee a robust physical layer.
CWDM4 Multiplexing & Dual 4-Lane EML / SiFotonics PD Optical Engines
The module houses two complete 4-lane CWDM (Coarse Wavelength Division Multiplexing) optical sub-assemblies. Each engine integrates four precision 1310nm-band EML (Electro-absorption Modulated Lasers) tuned to 1271nm, 1291nm, 1311nm, and 1331nm. On the receiving end, the module integrates an advanced SiFotonics photodiode array, providing superior responsivity, high linearity, and low dark current across all four CWDM channels. Internal optical MUX/DEMUX filters combine these four wavelengths onto a single optical path per LC port, eliminating chromatic dispersion penalties over 10km single-mode runs.
Twin-Port OSFP Closed Finned Top (IHS) Shrouded Thermal Architecture
Driving eight CWDM EML lasers and an advanced 800G DSP across 10km requires efficient thermal management. This transceiver is engineered in a specialized Closed Finned Top (IHS) OSFP form factor matching the Cisco OSFP800-2LR4-A2 specification. Unlike open-finned modules where airflow can spill laterally out of the heat sink, the closed shroud forces static pressure airflow longitudinally straight through the cooling channel. This dramatically increases convection velocity over internal heat pipes, keeping DSP and EML junction temperatures well below 70°C in high-density 32-port OSFP Cisco line cards.
Dual Duplex LC Interface & Standard Patch Panel Integration
Unlike parallel optics (DR8/SR8) that require 16-fiber MPO connectors, this module exposes two standard Duplex LC receptacles. The optical interface utilizes standard UPC (Ultra Physical Contact) polish connectors (standard blue LC boots), allowing seamless integration into existing fiber patch panels without needing specialized APC-to-UPC conversion patch cords.
Multi-Vendor Compatibility and CMIS 5.0 Diagnostics
Managing an 800G 10km single-mode fabric requires advanced software interfaces. This transceiver supports the Common Management Interface Specification to provide unprecedented visibility into the extended link state.
Cisco Hardware and OS Compatibility Validation
Engineered for seamless integration, the LO-CW800-2LR4C undergoes rigorous EEPROM coding and hardware validation in Cisco networking hardware. It is natively recognized by Cisco IOS XR and NX-OS as the OSFP800-2LR4-A2 module. It guarantees plug-and-play interoperability across Cisco 800G routing and switching platforms, avoiding proprietary vendor lock-outs and syslog warnings.
CMIS Rev 5.0 Management Interface
Fully compliant with CMIS 5.0, this module provides a standardized state machine for module initialization, allowing the host Cisco switch to manage firmware upgrades, configure datapath DSP parameters, and negotiate power classes before enabling the high-power long-reach EML lasers.
Per-Wavelength Real-Time Telemetry
Network operations centers (NOC) can actively monitor physical layer telemetry for all 8 optical wavelengths and 8 electrical channels via Cisco CLI commands. Metrics include independent TX Bias Current, TX Optical Power, and RX Optical Power for each specific CWDM wavelength channel (1271/1291/1311/1331nm), allowing for precise identification of optical attenuation or component degradation across 10km spans.
Selection Guide and Deployment Considerations
Deploying 800GBASE-2LR4 optics introduces specific single-mode cabling and link budget rules. Follow these critical engineering guidelines to ensure a flawless installation.
Closed Finned Top (IHS) vs Open Finned / Flat Top Selection
Ensure your Cisco switch chassis thermal ducting matches the module heat sink type:
- Closed Finned Top (This Module): Features a shrouded top heat sink designed for Cisco chassis with high static-pressure longitudinal airflow, preventing air spillover. Matches the Cisco OSFP800-2LR4-A2 specification.
- Open Finned Top: Features open-sided fins for general omnidirectional or open forced-air cages.
- Flat Top / RHS: Features a smooth top for liquid-cooled cold plates or chassis cages with internal riding heat sinks.
Duplex LC UPC Single-Mode Cabling Guidelines
Because this transceiver uses internal WDM wavelength multiplexing, cabling is remarkably simple compared to parallel optics:
- Cabling Required: Standard OS2 Single-Mode Fiber (SMF) duplex patch cords with Duplex LC/UPC (Blue) connectors.
- No MPO Needed: Do NOT use MPO-12 or MPO-16 cables. Each of the two ports on this transceiver accepts a standard 2-fiber LC duplex cable.
- Cleanliness: At 10km distances, dirty LC ferrules can introduce 1.0dB+ insertion loss, collapsing the optical link budget. Always clean LC connectors with a 1.25mm cleaner before insertion.
Mandatory Host-Side KP4 FEC Configuration (Inbuilt FEC: No)
Because this module relies on host-side DSP processing for error correction (Inbuilt FEC: No), Forward Error Correction (KP4 FEC / IEEE 802.3ck Clause 119) MUST be enabled on the host Cisco switch port. Without host-side FEC processing, 100G PAM4 signals over 10km SMF will suffer from high Bit Error Rates (BER) and link instability.