HOT CROSS-REFERENCE SEARCHES All Products
HR911105A Cisco GLC-LH-SMD Pulse J1011F21PNL LPJG0926HENL TE 2170704-1 SFP-10G-SR
POPULAR CATEGORIES
Matched Parts (Real-time ES) Use ↑ ↓ to select, Enter to open

Product Categories


Papua New Guinea LINK-PP LO-CW800-2FR4C 800G OSFP CWDM IHS/Closed Finned Top 2FR4 1310nm 2km Dual Duplex LC SMF Transceiver Module

Deploy 2km 800G Ethernet or native 2x400G FR4 breakouts over Single-Mode Fiber with the LINK-PP LO-CW800-2FR4C. Features Closed Finned Top (IHS) & Dual Duplex LC.
  • Compatible Brands: LINK-PP
  • Form Factor: OSFP
  • Data Rate: 800G
  • Distance: ≤2km
  • Type: Single Mode
  • Connector: MPO-12/APC
  • Model: 2FR4
  • Wavelength: 1270nm-1330nm
  • P/N: LO-CW800-2FR4C
  • Manufacture: LINK-PP
  • Compatible Brand: LINK-PP
  • Compatible P/N: LO-CW800-2FR4C

Product Description

Product Specifications

LINK-PP Part Number LO-CW800-2FR4C Vendor Name LINK-PP
Form Factor Twin-port OSFP IHS/Closed Finned Top Max Data Rate 850Gbps (8x 106.25Gbps)
Wavelength 1271nm, 1291nm, 1311nm and 1331nm Max Cable Distance 2km
Connector Dual Duplex LC/UPC Media SMF
Transmitter Type EML Receiver Type PIN
DDM/DOM Supported Operating Temperature Range 0°C to +70°C
Modulation (Electrical) 8x100G-PAM4 Modulation (Optical) Dual 4x100G-PAM4
Protocols OSFP MSA HW Rev 4.1, CMIS Rev 5.0, IEEE 802.3cu-2021, IEEE P802.3ck D2.2 Warranty 5 Years

LINK-PP LO-CW800-2FR4C 800GBASE-2FR4 / 2x400G-FR4 Twin-Port OSFP Optical Transceiver 2km Dual Duplex LC CWDM4 Closed Finned Top (IHS) for Cloud Networks

The LINK-PP LO-CW800-2FR4C is a high-performance, MSA-compliant 800GBASE-2FR4 / 2x400G-FR4 Twin-Port OSFP (Octal Small Form-factor Pluggable) optical transceiver engineered for hyperscale data center spine-leaf interconnects, campus backbones, and high-density routing fabrics spanning physical distances up to 2 kilometers. Designed with an Integrated Heat Sink (IHS / Closed Finned Top), this module features a specialized shrouded fin structure engineered to optimize static pressure airflow and direct heat removal in high-density 800G OSFP switch chassis.

Architected with an 8x 100G-PAM4 electrical interface and two independent CWDM4 optical engines multiplexing across 1271nm, 1291nm, 1311nm, and 1331nm grid wavelengths, the module achieves an aggregate data rate of 850Gbps (8x 106.25Gbps) over OS2 Single-Mode Fiber (SMF). Fully compliant with IEEE 802.3cu-2021, IEEE P802.3ck D2.2, OSFP MSA HW Rev 4.1, and CMIS 5.0, it integrates high-reliability 1310nm-band EML lasers paired with PIN photodiode receivers to guarantee a zero-packet-loss physical layer. Featuring a Dual Duplex LC/UPC interface, it allows network architects to deploy native 800G bandwidth or two independent 400G-FR4 links using standard duplex LC fiber patch cords without relying on complex MPO trunk cabling or breakout cassettes.

Application Topologies and Deployment Scenarios

The Twin-Port OSFP form factor has become the premier standard for high-density 800G and 2x 400G deployment in GPU-accelerated computing infrastructure due to its capability to double faceplate port density per switch slot.

Native 2x 400GBASE-FR4 Breakout via Standard Duplex LC Patch Cords

The primary architectural advantage of the Dual Duplex LC design is direct LC cable integration. Instead of deploying expensive MPO conversion cassettes or breakout Y-cables, network engineers can plug two standard duplex LC/UPC fiber patch cords directly into the front of a single 800G transceiver. This allows an 800G QSFP-DD/OSFP port on a core switch to operate seamlessly as two physically separate 400G-FR4 links, connecting directly to two legacy 400G switches up to 2km away.

Intra-Data Center Spine-to-Leaf Interconnects (2km SMF Reach)

When bridging ToR switches to core spine layers across expansive data center halls, distances frequently exceed 500-meter DR8 limits. Operating over OS2 single-mode fiber up to 2 kilometers, this module provides the optical power margin necessary for large-scale Clos network topologies, enabling lossless, microsecond-latency RDMA over Converged Ethernet (RoCEv2) traffic between AI compute nodes and storage arrays.

Eliminating MPO Cable Costs in Medium-Reach Fabrics

Deploying parallel optics (such as 800G DR8 or 2XDR4) over 2km distances requires 16 fibers (8 pairs) per module, driving up MPO trunk cable costs. By multiplexing 4 wavelengths internally onto a single pair of LC fibers (CWDM4 technology), this module allows operators to run high-density 800G traffic over standard 2-fiber LC duplex plant infrastructure, significantly lowering fiber plant CAPEX.

Physical Layer Design and Optical Performance Optimization

Transmitting 100Gbps per lane over 2 kilometers of single-mode fiber requires highly sophisticated optical WDM engineering to overcome chromatic dispersion. LINK-PP transceivers integrate advanced optical engines to guarantee a robust physical layer.

CWDM4 Multiplexing & Dual 4-Lane EML Optical Engines

The module houses two complete 4-lane CWDM (Coarse Wavelength Division Multiplexing) optical sub-assemblies. Each engine integrates four precision 1310nm-band EML (Electro-absorption Modulated Lasers) tuned to 1271nm, 1291nm, 1311nm, and 1331nm. Internal optical MUX/DEMUX filters combine these four wavelengths onto a single optical path per LC port. EML lasers provide extremely low chirp and narrow spectral width, eliminating chromatic dispersion penalties over 2km single-mode runs.

Twin-Port OSFP Closed Finned Top (IHS) Shrouded Thermal Architecture

Driving eight CWDM EML lasers and an advanced 800G retimer DSP across 2km requires efficient power management. This transceiver is engineered in a specialized Closed Finned Top (IHS) OSFP form factor. Unlike open-finned modules where airflow can spill laterally out of the heat sink, the closed shroud forces static pressure airflow longitudinally straight through the cooling channel. This dramatically increases convection velocity over internal heat pipes, keeping DSP and EML junction temperatures well below 70°C in high-density 32-port OSFP line cards.

Dual Duplex LC Interface & Standard Patch Panel Integration

Unlike parallel optics (DR8/SR8) that require 16-fiber MPO connectors, this module exposes two standard Duplex LC receptacles. The optical interface utilizes standard UPC (Ultra Physical Contact) polish connectors (standard blue LC boots), allowing seamless integration into existing fiber patch panels without needing specialized APC-to-UPC conversion patch cords.

Multi-Vendor Compatibility and CMIS 5.0 Diagnostics

Managing an 800G single-mode fabric requires advanced software interfaces. This transceiver supports the latest Common Management Interface Specification to provide unprecedented visibility into the extended link state.

Open-Standards OSFP MSA Interoperability

Engineered for universal open-standards deployments, the LO-CW800-2FR4C undergoes rigorous EEPROM coding and hardware validation. It guarantees plug-and-play interoperability in MSA-compliant 800G switching platforms, white-box networking hardware, and routing systems running open-source operating systems like SONiC or Cumulus Linux, avoiding proprietary vendor lock-outs.

CMIS Rev 5.0 Management Interface

Fully compliant with CMIS 5.0, this module provides a standardized state machine for module initialization, allowing host switch software to negotiate power classes, manage firmware updates, and configure datapath DSP parameters before enabling the high-power EML lasers.

Per-Wavelength Real-Time Telemetry

Network operations centers (NOC) can actively monitor physical layer telemetry for all 8 optical wavelengths and 8 electrical channels via DOM. Metrics include independent TX Bias Current, TX Optical Power, and RX Optical Power for each specific CWDM wavelength channel (1271/1291/1311/1331nm), allowing for precise identification of optical attenuation or component degradation across 2km spans.

Selection Guide and Deployment Considerations

Deploying 800GBASE-2FR4 optics introduces specific single-mode cabling and link budget rules. Follow these critical engineering guidelines to ensure a flawless installation.

Closed Finned Top (IHS) vs Open Finned / Flat Top Selection

Ensure your switch chassis thermal ducting matches the module heat sink type:

  • Closed Finned Top (This Module): Features a shrouded top heat sink designed for chassis with high static-pressure longitudinal airflow, preventing air spillover.
  • Open Finned Top: Features open-sided fins for general omnidirectional or open forced-air cages.
  • Flat Top / RHS: Features a smooth top for liquid-cooled cold plates or chassis cages with internal riding heat sinks.

Duplex LC UPC Single-Mode Cabling Guidelines

Because this transceiver uses internal WDM wavelength multiplexing, cabling is remarkably simple compared to parallel optics:

  • Cabling Required: Standard OS2 Single-Mode Fiber (SMF) duplex patch cords with Duplex LC/UPC (Blue) connectors.
  • No MPO Needed: Do NOT use MPO-12 or MPO-16 cables. Each of the two ports on this transceiver accepts a standard 2-fiber LC duplex cable.
  • Cleanliness: At 2km distances, dirty LC ferrules can introduce 1.0dB+ insertion loss, collapsing the optical link budget. Always clean LC connectors with a 1.25mm cleaner before insertion.

Mandatory Host-Side KP4 FEC Configuration

Ensure Forward Error Correction (KP4 FEC / IEEE 802.3ck Clause 119) is enabled on the host switch port. Without host-side FEC processing, 100G PAM4 signals over 2km SMF will suffer from high Bit Error Rates (BER) and link instability.

Download

Product Drawing