HOT CROSS-REFERENCE SEARCHES All Products
HR911105A Cisco GLC-LH-SMD Pulse J1011F21PNL LPJG0926HENL TE 2170704-1 SFP-10G-SR
POPULAR CATEGORIES
Matched Parts (Real-time ES) Use ↑ ↓ to select, Enter to open

Product Categories


Costa-Rica Dell GP-SFP-10GBX-D-80-I Compatible 10GBASE-BX SFP+ BiDi Transceiver with DOM

Deploy the Dell compatible GP-SFP-10GBX-D-80-I 10G BiDi SFP+ transceiver for 5G fronthaul and telecom networks. Features Cooled EML, APD receiver, 80km SMF reach, and -40 to 85°C industrial temp.
  • Compatible Brands: DELL
  • Form Factor: SFP+
  • Data Rate: 10G
  • Distance: ≤80km
  • Type: Single Mode
  • Connector: Simplex LC
  • Model: ZR
  • Wavelength: 1550nm-TX/1490nm-RX
  • P/N: LS-BL554910-80I
  • Manufacture: LINK-PP
  • Compatible Brand: DELL
  • Compatible P/N: GP-SFP-10GBX-D-80-I

Product Description

Product Specifications

LINK-PP Part Number LS-BL554910-80I Dell Part Number GP-SFP-10GBX-D-80-I
Form Factor SFP+ Max Data Rate 10.7 Gbps
Wavelength 1550nm-TX / 1490nm-RX Max Cable Distance 80km (Up to 100km)
Connector Simplex LC Media SMF (Single-Mode Fiber)
Optical Components Cooled EML / APD BiDi DOM / DDM Support Yes
TX Power -1.0 to +5.0 dBm RX Power -23.0 to -6.0 dBm
Receiver Sensitivity ≤ -25.0 dBm Receiver Overload -7.0 dBm
Industrial Temp Range -40°C to 85°C Protocols SFP+ MSA Compliant, CPRI, eCPRI

Dell GP-SFP-10GBX-D-80-I Compatible LINK-PP LS-BL554910-80I 10G BiDi SFP+ Optical Transceiver 1550nm-TX/1490nm-RX 80km Simplex LC for Industrial Telecom Networks

The LINK-PP LS-BL554910-80I is a carrier-grade, Dell GP-SFP-10GBX-D-80-I compatible 10G Bidirectional (BiDi) SFP+ optical transceiver designed for long-haul metropolitan area networks (MAN), Internet Service Provider (ISP) backbones, and 5G fronthaul connectivity. Engineered to transmit and receive data over a single strand of Single-Mode Fiber (SMF) via Wavelength Division Multiplexing (WDM), this module effectively doubles existing fiber capacity.

Built for extreme environments, this Industrial Temperature (-40°C to 85°C) transceiver integrates a premium Cooled EML laser and a high-sensitivity APD photodiode with a trans-impedance preamplifier (TIA). Compliant with CPRI, eCPRI, and SFP+ MSA standards, it delivers deterministic 10.7Gbps performance up to 80km, while providing network operations centers (NOC) with real-time DOM telemetry to ensure uninterrupted connectivity across critical long-haul infrastructure.

Application Topologies and Deployment Scenarios

Understanding the strategic value of 10G BiDi optical technology is crucial for optimizing CAPEX in telecom and enterprise networks. This transceiver is strictly optimized for environments where fiber strand availability is limited, and physical operating conditions are severe.

5G Fronthaul and Cell Tower Connectivity

Fully compliant with CPRI (Common Public Radio Interface) and eCPRI protocols, this industrial-grade module is standardly deployed in remote cell towers and outdoor enclosures. It provides high-bandwidth, low-latency uplinks between Baseband Units (BBU) and Remote Radio Heads (RRH), withstanding extreme weather fluctuations without signal degradation.

Metropolitan Area Networks (MAN) and ISP Backbones

For ISPs and regional carriers, bridging distances between metropolitan POPs (Points of Presence) requires high optical budgets. This 80km-rated transceiver allows architects to bypass intermediate optical amplifiers or repeaters in many long-haul edge-to-core network designs, dramatically simplifying the transmission topology.

Fiber Resource Optimization via BiDi WDM

In legacy deployments utilizing dual-fiber transceivers, scaling network capacity requires trenching new fiber—a massively expensive undertaking. By utilizing integrated WDM technology to multiplex TX and RX over a single Simplex LC strand, network engineers can instantly double their available fiber plant capacity for enterprise campus extensions and municipal networks.

Physical Layer Design and Optical Performance Optimization

Transmitting 10Gbps over 80 kilometers requires sophisticated optical engineering to overcome chromatic dispersion and severe signal attenuation. LINK-PP transceivers are built with superior chip-level components to ensure robust link integrity.

Cooled EML Transmitter and APD Receiver Architecture

The transmission core utilizes a Cooled EML (Electro-absorption Modulated Laser) operating at 1550nm, which offers significantly lower chirp and narrower spectral width than standard DML lasers, preventing data corruption over long distances. The receiving end employs a highly sensitive 1490nm APD (Avalanche Photodiode), capable of amplifying extremely weak optical signals after 80km of fiber attenuation.

Signal Integrity and 80km Optical Link Budget

The optical link budget is the critical metric for long-haul stability. This LS-BL554910-80I module boasts an exceptional optical power profile engineered for substantial distance:

  • Tx Output Power: -1.0 dBm to +5.0 dBm
  • Rx Sensitivity: Better than -25.0 dBm
  • Receiver Overload: -7.0 dBm
  • Optical Link Budget: ~24 dB margin (guaranteeing 80km reach, extending up to 100km on pristine OS2 fiber)

Hardened Industrial Thermal Management

Unlike commercial optics (0°C to 70°C), this industrial-rated transceiver is equipped with a specialized MCU control unit and thermal dissipation housing to operate flawlessly from -40°C to +85°C (-40°F to 185°F). It prevents laser wavelength drift in freezing winter cell towers and prevents component failure in unventilated summer street cabinets.

Multi-Vendor Compatibility and DOM/DDM Diagnostics

Telecom operators require optics that integrate universally with edge routers and core switches while providing deep visibility into the physical layer across spanning distances.

Carrier-Grade Switch and Router Compatibility

Undergoing stringent hardware and EEPROM validation, the LS-BL554910-80I is natively recognized as a Dell GP-SFP-10GBX-D-80-I. It bypasses proprietary vendor lock-outs, ensuring immediate plug-and-play operation in Dell Networking platforms, as well as seamlessly operating in MSA-compliant routing equipment from Cisco, Juniper, and Nokia used in carrier environments.

Real-Time Digital Diagnostic Monitoring (DOM/DDM)

Integrated DOM/DDM (compliant with SFF-8472) provides network administrators with real-time access to operational telemetry. Through standard SNMP or switch CLI, NOC engineers can actively monitor Transceiver Temperature, TX Bias Current, Vcc Voltage, TX Optical Power, and RX Optical Power.

Remote Link Health and Preventive Maintenance

For outdoor and long-haul deployments, dispatching a technician is costly. DOM telemetry allows IT teams to monitor gradual RX power degradation caused by micro-bends in aging fiber or weather-induced splice degradation, enabling proactive maintenance scheduling before a hard link failure occurs.

Selection Guide and Deployment Considerations

Deploying 80km BiDi optics involves strict adherence to physical layer rules. Below are critical engineering guidelines to prevent hardware damage and ensure optimal transmission.

BiDi Wavelength Pairing Requirement

Bidirectional transceivers must be deployed in complementary pairs. Because this module transmits at 1550nm and receives at 1490nm (1550nm-TX/1490nm-RX), the switch at the remote end of the fiber MUST be equipped with the exact opposite transceiver model (1490nm-TX/1550nm-RX) to establish a link.

Fiber Type and Distance Matching

To achieve the rated 10Gbps transmission distance, your physical cabling must meet the following parameters:

  • Fiber Standard: 9/125µm Single-Mode Fiber (OS1 or OS2; OS2 recommended for >50km)
  • Connector Type: Simplex LC (UPC Polish)
  • Max Cable Distance: 80km standard (Up to 100km depending on splice quality and fiber attenuation < 0.25 dB/km)

Common Deployment Mistakes in Long-Haul BiDi Networks

Avoid these frequent engineering errors to ensure a successful long-haul deployment:

  • Receiver Burnout (Crucial): This module features a highly sensitive APD receiver with an overload threshold of -7dBm. Never connect these modules back-to-back on a short fiber (< 20km) without using an inline optical attenuator (e.g., 10dB). Doing so will permanently destroy the receiver.
  • Mismatched Wavelength Pairs: Purchasing two identical 1550nm-TX/1490nm-RX modules will result in a failed link. Always order the matching pair.
  • Contaminated End-Faces: Dust on a Simplex LC connector over an 80km link will cause severe back-reflection and fatal dispersion penalties. Always wet/dry clean connectors before insertion.

Download